Abstract

Providers of critical infrastructure services strive to maintain the high availability of their SCADA systems. This paper reports on our experience designing, architecting, and evaluating the first survivable SCADA system-one that is able to ensure correct behavior with minimal performance degradation even during cyber attacks that compromise part of the system. We describe the challenges we faced when integrating modern intrusion-tolerant protocols with a conventional SCADA architecture and present the techniques we developed to overcome these challenges. The results illustrate that our survivable SCADA system not only functions correctly in the face of a cyber attack, but that it also processes in excess of 20 000 messages per second with a latency of less than 30 ms, making it suitable for even large-scale deployments managing thousands of remote terminal units.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tsg.2013.2269541

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 49

Metadata

Authors
Kirsch, J., Goose, S., Amir, Y., Wei, D., & Skare, P.
Venue
IEEE Transactions on Smart Grid
Published
2014-01
Volume
5
Issue
1
Pages
60-70
ISSN
  • 1949-3053 (ISSN-L)
  • 1949-3061
OpenAlex
W2061737329
Cited by
49
References
4
FWCI
5.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Survivable SCADA Via Intrusion-Tolerant Replication. https://app.cochat.ai/papers/10.1109/tsg.2013.2269541
The paper
Kirsch, J., Goose, S., Amir, Y., Wei, D., & Skare, P. (2014). Survivable SCADA Via Intrusion-Tolerant Replication. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2013.2269541

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.