Abstract
Providers of critical infrastructure services strive to maintain the high availability of their SCADA systems. This paper reports on our experience designing, architecting, and evaluating the first survivable SCADA system-one that is able to ensure correct behavior with minimal performance degradation even during cyber attacks that compromise part of the system. We describe the challenges we faced when integrating modern intrusion-tolerant protocols with a conventional SCADA architecture and present the techniques we developed to overcome these challenges. The results illustrate that our survivable SCADA system not only functions correctly in the face of a cyber attack, but that it also processes in excess of 20 000 messages per second with a latency of less than 30 ms, making it suitable for even large-scale deployments managing thousands of remote terminal units.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time, clocks, and the ordering of events in a distributed system
Lamport, L. (1978) · Communications of the ACM · doi:10.1145/359545.359563 · Cited by 8,488
The Byzantine generals problem
Lamport, L., Shostak, R., & Pease, M. (1982) · ACM Transactions on Programming Languages and Systems · doi:10.1145/357172.357176 · Cited by 6,023 · cited 3×
“tolerant protocol assumes that some of the protocol participants may be Byzantine [13] and act in an arbitrary manner.”
BackgroundPractical byzantine fault tolerance and proactive recovery
Castro, M., & Liskov, B. (2002) · ACM Transactions on Computer Systems · doi:10.1145/571637.571640 · Cited by 2,475 · cited 2×
“5As noted in [7], TCP is poorly suited to systems with potentially Byzantine receivers because, by failing to send acknowledgements, the Byzantine receivers can require correct replicas to buffer an unbounded number of messages.”
BackgroundImplementing fault-tolerant services using the state machine approach: a tutorial
Schneider, F. B. (1990) · ACM Computing Surveys · doi:10.1145/98163.98167 · Cited by 2,387 · cited 1×
“In this paper we make use of an intrusion-tolerant replication system, where replication is achieved via the state machine approach [14], [15].”
Method
Cited by
A Survey on SCADA Systems: Secure Protocols, Incidents, Threats and Tactics
Pliatsios, D., Sarigiannidis, P., Lagkas, T., & Sarigiannidis, A. G. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2020.2987688 · Cited by 320
“Kirsch et al. [143] present a robust SCADA system capable of surviving a partial compromise based on intrusion-tolerant state machine replication.”
BackgroundAssessing and augmenting SCADA cyber security: A survey of techniques
Nazir, S., Patel, S., & Patel, D. (2017) · Computers & Security · doi:10.1016/j.cose.2017.06.010 · Cited by 167
“SCADA control and monitoring projects remain in continuous operation [41] for many decades after commissioning.”
BackgroundSurvivable zero trust for cloud computing environments
Ferretti, L., Magnanini, F., Andreolini, M., & Colajanni, M. (2021) · Computers & Security · doi:10.1016/j.cose.2021.102419 · Cited by 69
Metadata
- Authors
- Kirsch, J., Goose, S., Amir, Y., Wei, D., & Skare, P.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2014-01
- Volume
- 5
- Issue
- 1
- Pages
- 60-70
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2061737329
- Cited by
- 49
- References
- 4
- FWCI
- 5.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Survivable SCADA Via Intrusion-Tolerant Replication. https://app.cochat.ai/papers/10.1109/tsg.2013.2269541
- The paper
- Kirsch, J., Goose, S., Amir, Y., Wei, D., & Skare, P. (2014). Survivable SCADA Via Intrusion-Tolerant Replication. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2013.2269541
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.