Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 253

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Indirect Finite Control Set Model Predictive Control of Modular Multilevel Converters

Open access
Vatani, Mohsen, Bahrani, Behrooz, Saeedifard, Maryam, Hovd, Morten·2015·IEEE Transactions on Smart Grid

Abstract

The modular multilevel converter (MMC) is a potential candidate for medium/high-power applications, specifically for high-voltage direct current transmission systems. One of the main challenges in the control of an MMC is to eliminate/minimize the circulating currents while the capacitor voltages are maintained balanced. This paper proposes a control strategy for the MMC using finite control set model predictive control (FCS-MPC). A bilinear mathematical model of the MMC is derived and discretized to predict the states of the MMC one step ahead. Within each switching cycle, the best switching state of the MMC is selected based on evaluation and minimization of a defined cost function. The defined cost function is aimed at the elimination of the MMC circulating currents, regulating the arm voltages, and controlling the ac-side currents. To reduce the calculation burden of the MPC, the submodule (SM) capacitor voltage balancing controller based on the conventional sorting method is combined with the proposed FCS-MPC strategy. The proposed FCS-MPC strategy determines the number of inserted/bypassed SMs within each arm of the MMC while the sorting algorithm is used to keep the SM capacitor voltages balanced. Using this strategy, only the summation of SM capacitor voltages of each arm is required for control purposes, which simplifies the communication among the SMs and the central controller. This paper also introduces a modified switching strategy, which not only reduces the calculation burden of the FCS-MPC strategy even more, but also simplifies the SM capacitor voltage balancing algorithm. In addition, this strategy reduces the SM switching frequency and power losses by avoiding the unnecessary switching transitions. The performance of the proposed strategies for a 20-level MMC is evaluated based on the time-domain simulation studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tsg.2014.2377112

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 253

Metadata

Authors
Vatani, M., Bahrani, B., Saeedifard, M., & Hovd, M.
Venue
IEEE Transactions on Smart Grid
Published
2015-05
Volume
6
Issue
3
Pages
1520-1529
ISSN
  • 1949-3053 (ISSN-L)
  • 1949-3061
OpenAlex
W2047937098
Cited by
253
References
20
FWCI
9.37
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Indirect Finite Control Set Model Predictive Control of Modular Multilevel Converters. https://app.cochat.ai/papers/10.1109/tsg.2014.2377112
The paper
Vatani, M., Bahrani, B., Saeedifard, M., & Hovd, M. (2015). Indirect Finite Control Set Model Predictive Control of Modular Multilevel Converters. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2014.2377112

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.