The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A Fully Distributed Reactive Power Optimization and Control Method for Active Distribution Networks
Open accessAbstract
This paper presents a fully distributed reactive power optimization algorithm that can obtain the global optimum solution of nonconvex problems for distribution networks (DNs) without requiring a central coordinator. Second-order conic relaxation is used to achieve exact convexification. A fully distributed second-order cone programming solver (D-SOCP) is formulated corresponding to the given division of areas based on the alternating direction method of multipliers (ADMM) algorithm, which is greatly simplified by exploiting the structure of active DNs. The problem is solved for each area with very little interchange of boundary information between neighboring areas. D-SOCP is extended by using a varying penalty parameter to improve convergence. A proof of its convergence is also given. The effectiveness of the method is demonstrated via numerical simulations using the IEEE 69-bus, 123-bus DNs, and a real 1066-bus distribution system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., Parikh, N., Chu, E., Peleato, B., & Eckstein, J. (2011) · Foundations and Trends® in Machine Learning · doi:10.1561/2200000016 · Cited by 17,075
Branch Flow Model: Relaxations and Convexification—Part I
Farivar, M., & Low, S. H. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2255317 · Cited by 1,541
Distribution System Modeling and Analysis
Kersting, W. (2012) · Electric Power Engineering Series · doi:10.1201/b12056-31 · Cited by 1,241
Cited by
A survey of distributed optimization
Yang, T., Yi, X., Wu, J., Yuan, Y., Wu, D., Meng, Z., Hong, Y., Wang, H., Lin, Z., & Johansson, K. H. (2019) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2019.05.006 · Cited by 913
Antoniadou-Plytaria, K. E., Kouveliotis-Lysikatos, I. N., Georgilakis, P. S., & Hatziargyriou, N. D. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2679238 · Cited by 545
Chai, Y., Guo, L., Wang, C., Zhao, Z., Du, X., & Pan, J. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2018.2813400 · Cited by 265
Learning Optimal Solutions for Extremely Fast AC Optimal Power Flow
Zamzam, A. S., & Baker, K. (2020) · 2020 IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids (SmartGridComm) · doi:10.1109/smartgridcomm47815.2020.9303008 · Cited by 206
Li, S., Wu, W., & Lin, Y. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3166274 · Cited by 54
Self-citation
Metadata
- Authors
- Zheng, W., Wu, W., Zhang, B., Sun, H., & Liu, Y.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2015
- Pages
- 1-1
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2002154164
- Cited by
- 371
- References
- 3
- FWCI
- 11.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Fully Distributed Reactive Power Optimization and Control Method for Active Distribution Networks. https://app.cochat.ai/papers/10.1109/tsg.2015.2396493
- The paper
- Zheng, W., Wu, W., Zhang, B., Sun, H., & Liu, Y. (2015). A Fully Distributed Reactive Power Optimization and Control Method for Active Distribution Networks. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2015.2396493
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.