Smart Meter Data Analytics for Distribution Network Connectivity Verification
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Many utilities have the data quality problem with the geographical information system (GIS) records at distribution level. This affects many business functions of a utility, including asset management, outage response, and workforce safety. For correcting connectivity errors in the GIS representation of the distribution network topology, BC Hydro has developed an in-house algorithm. The algorithm leverages smart meter interval measurements and identifies the neighboring meters by voltage profile correlation analysis. It also predicts customers' upstream and downstream location relationship by voltage magnitude comparisons. The output of the algorithm is then compared with the existing GIS records to correct any errors in it. This paper presents in detail the algorithm and the promising testing results within the practical BC Hydro system. Challenges for underground services are demonstrated. The algorithm's potential use for phase detection by collectively leveraging smart meter and feeder meter data is explored. It shows encouraging results when applied in a downstream section of a large feeder.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long Term Probabilistic Load Forecasting and Normalization With Hourly Information
Hong, T., Wilson, J., & Xie, J. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2274373 · Cited by 382
Goncalves Da Silva, P., Ilic, D., & Karnouskos, S. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2278868 · Cited by 217
Identification of power distribution network topology via voltage correlation analysis
Bolognani, S., Bof, N., Michelotti, D., Muraro, R., & Schenato, L. (2013) · 52nd IEEE Conference on Decision and Control · doi:10.1109/cdc.2013.6760120 · Cited by 200
Analysis of Conservation Voltage Reduction Effects Based on Multistage SVR and Stochastic Process
Wang, Z., Begovic, M. M., & Wang, J. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2279836 · Cited by 77
Distribution network topology error correction using smart meter data analytics
Luan, W., Peng, J., Maras, M., & Lo, J. (2013) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesmg.2013.6672786 · Cited by 53
Self-citation
Cited by
Review of Smart Meter Data Analytics: Applications, Methodologies, and Challenges
Wang, Y., Chen, Q., Hong, T., & Kang, C. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2818167 · Cited by 1,369
A Survey on State Estimation Techniques and Challenges in Smart Distribution Systems
Dehghanpour, K., Wang, Z., Wang, J., Yuan, Y., & Bu, F. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2870600 · Cited by 485
Energetics Systems and artificial intelligence: Applications of industry 4.0
Ahmad, T., Zhu, H., Zhang, D., Tariq, R., Bassam, A., Ullah, F., AlGhamdi, A. S., & Alshamrani, S. S. (2022) · Energy Reports · doi:10.1016/j.egyr.2021.11.256 · Cited by 369
Smart Grid Metering Networks: A Survey on Security, Privacy and Open Research Issues
Kumar, P., Lin, Y., Bai, G., Paverd, A., Dong, J. S., & Martin, A. (2019) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2019.2899354 · Cited by 333
Big data issues in smart grid – A review
Tu, C., He, X., Shuai, Z., & Jiang, F. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.05.134 · Cited by 256
Metadata
- Authors
- Luan, W., Peng, J., Maras, M., Lo, J., & Harapnuk, B.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2015-07
- Volume
- 6
- Issue
- 4
- Pages
- 1964-1971
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W1986130852
- Cited by
- 287
- References
- 5
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.