The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Distribution System State Estimation Based on Nonsynchronized Smart Meters
Abstract
Distribution systems are undergoing many enhancements and developments to enable the future smart grid, and distribution system state estimation (DSSE) provides the control centers with the information necessary for several of its applications and operational functions. However, the quality of DSSE typically suffers from a lack of adequate/accurate measurements. Recently, many electric utilities have started to install fairly accurate smart meters throughout their distribution networks, which create an opportunity to achieve higher quality DSSE. However, the signals provided by smart meters are generally not synchronized and the difference between the measurement times of smart meters can be significant. Therefore, a complete snapshot of the entire distribution system may not be available. This paper proposes a method to deal with the issue of nonsynchronized measurements coming from smart meters based on the credibility of each available measurement and appropriately adjusting the variance of the measurement devices. To illustrate the effectiveness of the proposed method, two IEEE benchmark systems are used. The results show that the proposed method is robust and improves the accuracy of DSSE compared with the traditional DSSE approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An analysis of variance test for normality (complete samples)
SHAPIRO, S. S., & WILK, M. B. (1965) · Biometrika · doi:10.1093/biomet/52.3-4.591 · Cited by 23,480
Asymptotic Theory of Certain "Goodness of Fit" Criteria Based on Stochastic Processes
Anderson, T. W., & Darling, D. A. (1952) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177729437 · Cited by 3,542 · cited 1×
“a set of data is normally distributed [25]–[28].”
Background
Cited by
A Review on Distribution System State Estimation
Primadianto, A., & Lu, C.-N. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2632156 · Cited by 652
A Survey on State Estimation Techniques and Challenges in Smart Distribution Systems
Dehghanpour, K., Wang, Z., Wang, J., Yuan, Y., & Bu, F. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2870600 · Cited by 485
Bayesian State Estimation for Unobservable Distribution Systems Via Deep Learning
Mestav, K. R., Luengo-Rozas, J., & Tong, L. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2919157 · Cited by 216
Metadata
- Authors
- Alimardani, A., Therrien, F., Atanackovic, D., Jatskevich, J., & Vaahedi, E.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2015-11
- Volume
- 6
- Issue
- 6
- Pages
- 2919-2928
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W1938290551
- Cited by
- 197
- References
- 2
- FWCI
- 7.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.