The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Enhancing Power System Resilience Through Hierarchical Outage Management in Multi-Microgrids
Abstract
This paper proposes a hierarchical outage management scheme to enhance the resilience of a smart distribution system comprised of multi-microgrids against unexpected disaster events. In this regard, after identifying the main features and requirements for a resilient outage management scheme, an appropriate framework is devised and the roles and tasks of different management entities in a multi-microgrids system are introduced. Based on this framework, the microgrids schedule their available resources in the first stage using a novel model predictive control-based algorithm. In the second stage, distribution system operator coordinates the possible power transfers among the microgrids and utilizes the unused capacities of microgrids' resources for feeding the unserved loads in stage I. The general optimization model that needs to be run is formulated as a mixed integer linear programming problem and a novel index is presented to quantify the performance of the proposed method. The developed scheme is implemented on a test system and its effectiveness in confronting with different outage events is demonstrated through realistic case studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Chandorkar, M., Lee, T.-L., & Loh, P. C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194969 · Cited by 1,976
Smart Distribution: Coupled Microgrids
Lasseter, R. H. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2114630 · Cited by 1,130
Research on Resilience of Power Systems Under Natural Disasters—A Review
Wang, Y., Chen, C., Wang, J., & Baldick, R. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2429656 · Cited by 1,116
Microgrids and Active Distribution Networks
Chowdhury, S., Chowdhury, S., & Crossley, P. A. (2009) · Institution of Engineering and Technology eBooks · doi:10.1049/pbrn006e · Cited by 973
Resilient Distribution System by Microgrids Formation After Natural Disasters
Chen, C., Wang, J., Qiu, F., & Zhao, D. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2429653 · Cited by 944
The Grid: Stronger, Bigger, Smarter?: Presenting a Conceptual Framework of Power System Resilience
Panteli, M., & Mancarella, P. (2015) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2015.2397334 · Cited by 851
Panteli, M., & Mancarella, P. (2017) · IEEE Systems Journal · doi:10.1109/jsyst.2015.2389272 · Cited by 670
Self-Healing Resilient Distribution Systems Based on Sectionalization Into Microgrids
Wang, Z., & Wang, J. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2389753 · Cited by 629
Resiliency-Oriented Microgrid Optimal Scheduling
Khodaei, A. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2311465 · Cited by 434
Decentralized Energy Management System for Networked Microgrids in Grid-Connected and Islanded Modes
Wang, Z., Chen, B., Wang, J., & kim, J. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2427371 · Cited by 405
A centralized optimal energy management system for microgrids
Olivares, D. E., Cañizares, C. A., & Kazerani, M. (2011) · IEEE Power and Energy Society General Meeting (PESGM) · doi:10.1109/pes.2011.6039527 · Cited by 220
Risk Analysis for Distribution Systems in the Northeast U.S. Under Wind Storms
Li, G., Zhang, P., Luh, P. B., Li, W., Bie, Z., Serna, C., & Zhao, Z. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2286171 · Cited by 203
Coordinated Multi-Microgrids Optimal Control Algorithm for Smart Distribution Management System
Wu, J., & Guan, X. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2269481 · Cited by 200
Power System Reliability Impact of Energy Storage Integration With Intelligent Operation Strategy
Xu, Y., & Singh, C. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2278482 · Cited by 146
Xu, Y., & Singh, C. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2186830 · Cited by 145
A Multiobjective Approach to Multimicrogrid System Design
Chiu, W.-Y., Sun, H., & Poor, H. V. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2399497 · Cited by 117
Multi-microgrid control systems (MMCS)
Ng, E. J., & El‐Shatshat, R. (2010) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2010.5589720 · Cited by 96
Japan's Pivot to Resilience: How Two Microgrids Fared After the 2011 Earthquake
Marnay, C., Aki, H., Hirose, K., et al. (2015) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2015.2397333 · Cited by 89
A Multiobjective Approach to Multimicrogrid System Design
Chiu, W., Sun, H., & Poor, H. V. (2024) · Figshare · Cited by 87
Distribution Systems: Reliable But Not Resilient? [In My View]
Liu, C. (2015) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2015.2397332 · Cited by 53
Cited by
Distributed Power-Generation Systems and Protection
Blaabjerg, F., Yang, Y., Yang, D., & Wang, X. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2696878 · Cited by 671
Networked Microgrids for Enhancing the Power System Resilience
Li, Z., Shahidehpour, M., Aminifar, F., Alabdulwahab, A., & Al-Turki, Y. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2685558 · Cited by 640
Power System Resilience: Current Practices, Challenges, and Future Directions
Bhusal, N., Abdelmalak, M., Kamruzzaman, M., & Benidris, M. (2020) · IEEE Access · doi:10.1109/access.2020.2968586 · Cited by 456
A Review of the Measures to Enhance Power Systems Resilience
Mahzarnia, M., Moghaddam, M. P., Baboli, P. T., & Siano, P. (2020) · IEEE Systems Journal · doi:10.1109/jsyst.2020.2965993 · Cited by 385
Networked Microgrids for Grid Resilience, Robustness, and Efficiency: A Review
Chen, B., Wang, J., Lu, X., Chen, C., & Zhao, S. (2021) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2020.3010570 · Cited by 344
Metadata
- Authors
- Farzin, H., Fotuhi-Firuzabad, M., & Moeini-Aghtaie, M.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2016-11
- Volume
- 7
- Issue
- 6
- Pages
- 2869-2879
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2343206695
- Cited by
- 398
- References
- 20
- FWCI
- 37.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.