CoChat

Power System Structural Vulnerability Assessment Based on an Improved Maximum Flow Approach

Fang, Jiakun, Su, Chi, Chen, Zhe, Sun, Haishun, Lund, Per · 2018 · IEEE Transactions on Smart Grid
Cited by 161

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

With the increasing complexity of the power grid and the concerns on major blackouts, there is an urgent need for an efficient and effective tool to assess the power system structural vulnerability. To tackle this challenge, this paper proposes a maximum flow-based complex network approach to identify the critical lines in a system. The proposed method consists of two major steps. First, the power network is modeled as a graph with edges (transmission lines, transformers, etc.) and nodes (buses, substations, etc.). The critical scenarios are identified by using the principal component analysis and convex hull. Then the second step is to use an improved maximum flow-based complex network approach for topology analysis. Weighted vertices in the network are considered, enabling taking the selected operating conditions into consideration when identifying the vulnerable lines. The proposed method is validated using the western Danish power system. The vulnerable lines in the network are ranked. Simulation results demonstrate the effectiveness of the method by intentional attacks and comparison with the planning strategy from the system operator.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tsg.2016.2565619

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 161

Metadata

Authors
Fang, J., Su, C., Chen, Z., Sun, H., & Lund, P.
Venue
IEEE Transactions on Smart Grid
Published
2018-03
Volume
9
Issue
2
Pages
777-785
ISSN
  • 1949-3053 (ISSN-L)
  • 1949-3061
OpenAlex
W2381162371
Cited by
161
References
34
FWCI
6.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.