The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Innovation Rate Sampling of Pulse Streams With Application to Ultrasound Imaging
Open accessAbstract
Signals comprised of a stream of short pulses appear in many applications including bioimaging and radar. The recent finite rate of innovation framework, has paved the way to low rate sampling of such pulses by noticing that only a small number of parameters per unit time are needed to fully describe these signals. Unfortunately, for high rates of innovation, existing sampling schemes are numerically unstable. In this paper we propose a general sampling approach which leads to stable recovery even in the presence of many pulses. We begin by deriving a condition on the sampling kernel which allows perfect reconstruction of periodic streams from the minimal number of samples. We then design a compactly supported class of filters, satisfying this condition. The periodic solution is extended to finite and infinite streams and is shown to be numerically stable even for a large number of pulses. High noise robustness is also demonstrated when the delays are sufficiently separated. Finally, we process ultrasound imaging data using our techniques and show that substantial rate reduction with respect to traditional ultrasound sampling schemes can be achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
Multiple emitter location and signal parameter estimation
Schmidt, R. (1986) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.1986.1143830 · Cited by 14,718
Bertsekas, D. P. (1997) · Journal of the Operational Research Society · doi:10.1038/sj.jors.2600425 · Cited by 11,726
Fundamentals of Statistical Signal Processing: Estimation Theory
Sengijpta, S. K. (1995) · Technometrics · doi:10.1080/00401706.1995.10484391 · Cited by 11,076
Fundamentals of statistical signal processing: Estimation theory
Prasad, K. V. (1994) · Control Engineering Practice · doi:10.1016/0967-0661(94)90195-3 · Cited by 7,902
ESPRIT-estimation of signal parameters via rotational invariance techniques
Roy, R., & Kailath, T. (1989) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/29.32276 · Cited by 7,289
Fundamentals Of Statistical Signal Processing
Kay, S. (2001) · International Linear Collider · Cited by 3,642
Mangasarian, O. L. (1994) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611971255 · Cited by 3,220
Hoffman, K. A. (1961) · Cited by 2,706
Introduction to Spectral Analysis
(2005) · Technometrics · doi:10.1198/tech.2005.s841 · Cited by 1,933
Cited by
Structured Compressed Sensing: From Theory to Applications
Duarte, M. F., & Eldar, Y. C. (2011) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2011.2161982 · Cited by 1,128
Self-citationDeep learning in ultrasound imaging
van Sloun, R. J. G., Cohen, R., & Eldar, Y. C. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2932116 · Cited by 316
Self-citationXampling: Signal Acquisition and Processing in Union of Subspaces
Mishali, M., Eldar, Y. C., & Elron, A. J. (2011) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2011.2161472 · Cited by 311
Self-citation
Metadata
- Authors
- Tur, R., Eldar, Y. C., & Friedman, Z.
- Venue
- IEEE Transactions on Signal Processing
- Published
- 2011-04
- Volume
- 59
- Issue
- 4
- Pages
- 1827-1842
- ISSN
- 1053-587X (ISSN-L)
- 1941-0476
- OpenAlex
- W2138787877
- Cited by
- 296
- References
- 26
- FWCI
- 42.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Innovation Rate Sampling of Pulse Streams With Application to Ultrasound Imaging. https://app.cochat.ai/papers/10.1109/tsp.2011.2105480
- The paper
- Tur, R., Eldar, Y. C., & Friedman, Z. (2011). Innovation Rate Sampling of Pulse Streams With Application to Ultrasound Imaging. IEEE Transactions on Signal Processing. https://doi.org/10.1109/tsp.2011.2105480
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.