The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Compressed Beamforming in Ultrasound Imaging
Open accessAbstract
Emerging sonography techniques often require increasing the number of transducer elements involved in the imaging process. Consequently, larger amounts of data must be acquired and processed. The significant growth in the amounts of data affects both machinery size and power consumption. Within the classical sampling framework, state of the art systems reduce processing rates by exploiting the bandpass bandwidth of the detected signals. It has been recently shown, that a much more significant sample-rate reduction may be obtained, by treating ultrasound signals within the Finite Rate of Innovation framework. These ideas follow the spirit of Xampling, which combines classic methods from sampling theory with recent developments in Compressed Sensing. Applying such low-rate sampling schemes to individual transducer elements, which detect energy reflected from biological tissues, is limited by the noisy nature of the signals. This often results in erroneous parameter extraction, bringing forward the need to enhance the SNR of the low-rate samples. In our work, we achieve SNR enhancement, by beamforming the sub-Nyquist samples obtained from multiple elements. We refer to this process as “compressed beamforming”. Applying it to cardiac ultrasound data, we successfully image macroscopic perturbations, while achieving a nearly eightfold reduction in sample-rate, compared to standard techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017
Cited by
Xenaki, A., Gerstoft, P., & Mosegaard, K. (2014) · The Journal of the Acoustical Society of America · doi:10.1121/1.4883360 · Cited by 326
Deep learning in ultrasound imaging
van Sloun, R. J. G., Cohen, R., & Eldar, Y. C. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2932116 · Cited by 316
Self-citation
Metadata
- Authors
- Wagner, N., Eldar, Y. C., & Friedman, Z.
- Venue
- IEEE Transactions on Signal Processing
- Published
- 2012-09
- Volume
- 60
- Issue
- 9
- Pages
- 4643-4657
- ISSN
- 1053-587X (ISSN-L)
- 1941-0476
- OpenAlex
- W2111273705
- Cited by
- 208
- References
- 1
- FWCI
- 15.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Compressed Beamforming in Ultrasound Imaging. https://app.cochat.ai/papers/10.1109/tsp.2012.2200891
- The paper
- Wagner, N., Eldar, Y. C., & Friedman, Z. (2012). Compressed Beamforming in Ultrasound Imaging. IEEE Transactions on Signal Processing. https://doi.org/10.1109/tsp.2012.2200891
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.