Elliptic Localization: Performance Study and Optimum Receiver Placement
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Range based localization often relies on TOA that creates a circular contour or TDOA that yields hyperbolic surface to determine the position of an emitting object. Another approach that has gained attention recently is elliptic localization. Elliptic localization uses an active transmitter to send out a signal and several receivers to acquire the reflected or relayed signal from an object to obtain its location. This paper performs a fundamental investigation on the performance of elliptic localization, for both the synchronous and asynchronous cases between the transmitter and the receivers. Their performance is also characterized with respect to the hyperbolic localization. The study is based on the Cramér–Rao lower bound (CRLB) for the object location under Gaussian measurement noise as well as Gaussian errors in the transmitter and receiver positions. When the receiver positions are controllable, we derive the optimum receiver placement for elliptic positioning to improve the localization accuracy. We conclude the study with simulation results to demonstrate the elliptic localization performance using the CRLBs and the Maximum Likelihood estimators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The generalized correlation method for estimation of time delay
Knapp, C., & Carter, G. (1976) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1976.1162830 · Cited by 4,433 · cited 1×
“Depending on whether the transmitter and receivers are synchronized, we have the synchronous elliptic (SE) positioning and the asynchronous elliptic (AE) positioning.”
Background
Cited by
Optimal Geometry Analysis for Multistatic TOA Localization
Nguyen, N. H., & Dogancay, K. (2016) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2016.2566611 · Cited by 182
“The inequality in (28) implies that the area of TOA error ellipse effectively increases if receiver i is relocated from its optimal bearing angle.”
BackgroundMethodInfluential
Metadata
- Authors
- Rui, L., & Ho, K. C.
- Venue
- IEEE Transactions on Signal Processing
- Published
- 2014-09
- Volume
- 62
- Issue
- 18
- Pages
- 4673-4688
- ISSN
- 1053-587X (ISSN-L)
- 1941-0476
- OpenAlex
- W2001886371
- Cited by
- 201
- References
- 1
- FWCI
- 4.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.