The DOI matches its Crossref record.
Provision of Inertial and Primary Frequency Control Services Using Offshore Multiterminal HVDC Networks
Open accessAbstract
This paper addresses the problem of providing frequency control services, including inertia emulation and primary frequency control, from offshore wind farms connected through a multiterminal HVDC network. The proposed strategy consists of a cascading control mechanism based on dc voltage regulation at the onshore converters and frequency regulation at the offshore converters. The control scheme involves only local measurements and actions avoiding security and reliability issues of control structures based on remote information. The effectiveness of the proposed strategy is illustrated in a test system that consists of two nonsynchronous areas linked by a multiterminal HVDC grid where two offshore wind farms are also connected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Synchronous Generator Emulation Control Strategy for Voltage Source Converter (VSC) Stations
Guan, M., Pan, W., Zhang, J., Hao, Q., Cheng, J., & Zheng, X. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2384498 · Cited by 432
Huang, L., Xin, H., Wang, Z., Wu, K., Wang, H., Hu, J., & Lu, C. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2740424 · Cited by 342
Frequency support from modular multilevel converter based multi-terminal HVDC schemes
Adeuyi, O. D., Cheah-Mane, M., Liang, J., Jenkins, N., Wu, Y., Li, C., & Wu, X. (2015) · 2015 IEEE Power & Energy Society General Meeting · doi:10.1109/pesgm.2015.7286086 · Cited by 56
Metadata
- Authors
- Silva, B., Moreira, C. L., Seca, L., Phulpin, Y., & Pecas Lopes, J. A.
- Venue
- IEEE Transactions on Sustainable Energy
- Published
- 2012-10
- Volume
- 3
- Issue
- 4
- Pages
- 800-808
- ISSN
- 1949-3029 (ISSN-L)
- 1949-3037
- OpenAlex
- W2041761580
- Cited by
- 231
- References
- 0
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.