Optimal Local Reactive Power Control by PV Inverters
The DOI matches its Crossref record.
Abstract
The high penetration of photovoltaic (PV) generators leads to a voltage rise in the distribution network. To comply with grid standards, distribution system operators need to limit this voltage rise. Reactive power control is one of the most proposed remedies. A popular form of reactive power control is an active power dependent characteristic to define the reactive power control of a PV generator. This standard Q(P) characteristic is a simple curve, which is not adapted to the specific situation in the grid. Therefore, this work proposes a method to define the optimal Q(P) curve. The optimal Q( P) curve is represented as a piecewise constant or a piecewise linear function. The parameters are optimized based on historical smart meter information, to obtain a Q(P) curve that keeps the voltage within limits throughout the whole year, with a minimal amount of reactive power. An easy to solve convex optimization problem defines the parameters. The method is applied to unbalanced three-phase four-wire systems. Several simulations with realistic data are performed on an existing distribution network to compare the optimal Q(P) curve with standard Q(P) and Q (V) curves.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tushar, W., Yuen, C., Saha, T. K., Morstyn, T., Chapman, A. C., Alam, M. J. E., Hanif, S., & Poor, H. V. (2021) · Applied Energy · doi:10.1016/j.apenergy.2020.116131 · Cited by 523
Sun, X., & Qiu, J. (2021) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2021.3052998 · Cited by 289
A Multi-Agent Deep Reinforcement Learning Based Voltage Regulation Using Coordinated PV Inverters
Cao, D., Hu, W., Zhao, J., Huang, Q., Chen, Z., & Blaabjerg, F. (2020) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3000652 · Cited by 275
Optimal local volt/var control for photovoltaic inverters in active distribution networks
Sun, X., Qiu, J., & Zhao, J. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2021.3080039 · Cited by 111
Data-driven combined central and distributed volt/var control in active distribution networks
Sun, X., Qiu, J., Tao, Y., & Zhao, J. (2023) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3213587 · Cited by 42
Metadata
- Authors
- Weckx, S., & Driesen, J.
- Venue
- IEEE Transactions on Sustainable Energy
- Published
- 2016-10
- Volume
- 7
- Issue
- 4
- Pages
- 1624-1633
- ISSN
- 1949-3029 (ISSN-L)
- 1949-3037
- OpenAlex
- W2401391162
- Cited by
- 137
- References
- 0
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Local Reactive Power Control by PV Inverters. https://app.cochat.ai/papers/10.1109/tste.2016.2572162
- The paper
- Weckx, S., & Driesen, J. (2016). Optimal Local Reactive Power Control by PV Inverters. IEEE Transactions on Sustainable Energy. https://doi.org/10.1109/tste.2016.2572162
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.