Power Reserves Control for PV Systems With Real-Time MPP Estimation via Curve Fitting
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
In order for a photovoltaic (PV) system to provide a full range of ancillary services to the gird, including frequency response, it has to maintain active power reserves. In this paper, a new control scheme for the dc/dc converter of a two-stage PV system is introduced, which permits operation at a reduced power level, estimating the available power (maximum power point-MPP) at the same time. This control scheme is capable of regulating the output power to any given reference, from near-zero to 100% of the available power. The proposed MPP estimation algorithm applies curve fitting on voltage and current measurements obtained during operation to determine the MPP in real time. This is the first method in the literature to use the nonsimplified single-diode model for the determination of the MPP and the five model parameters while operating at a curtailed power level. The developed estimation technique exhibits very good accuracy and robustness in the presence of noise and rapidly changing environmental conditions. The effectiveness of the control scheme is validated through simulation and experimental tests using a 2-kW PV array and a dc/dc converter prototype at constant and varying irradiance conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparison of Photovoltaic Array Maximum Power Point Tracking Techniques
Esram, T., & Chapman, P. L. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.874230 · Cited by 5,425 · cited 1×
“P&O and INC, perturb the converter duty cycle to introduce additional variation of the operating point [18].”
BackgroundDynamic maximum power point tracking of photovoltaic arrays using ripple correlation control
Esram, T., Kimball, J. W., Krein, P. T., Chapman, P. L., & Midya, P. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.880242 · Cited by 592
Omran, W. A., Kazerani, M., & Salama, M. M. A. (2011) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2010.2062515 · Cited by 395
Regulation of Photovoltaic Voltage
Xiao, W., Dunford, W. G., Palmer, P., & Capel, A. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.893059 · Cited by 390 · cited 2×
“The continuous-time transfer function of the small-signal model of this circuit can be found in [35], with the duty”
BackgroundA New Frequency Regulation Strategy for Photovoltaic Systems Without Energy Storage
Xin, H., Liu, Y., Wang, Z., Gan, D., & Yang, T. (2013) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2013.2261567 · Cited by 277 · cited 5×
“Further and more importantly, in this case power regulation over the entire range from near-zero to maximum power Pmp can be easily achieved [11].”
BackgroundMethodInfluentialThe results of performance measurements of field‐aged crystalline silicon photovoltaic modules
Skoczek, A., Sample, T., & Dunlop, E. D. (2009) · Progress in Photovoltaics: Research and Applications · doi:10.1002/pip.874 · Cited by 276 · cited 1×
“75% per year for crystalline PV modules [34], a scan frequency of once per month or year should suffice.”
BackgroundWu, D., Tang, F., Dragicevic, T., Vasquez, J. C., & Guerrero, J. M. (2014) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2358612 · Cited by 268 · cited 3×
“switch between operating modes (MPPT or Reserves) as done in other works [4], [10], [11], [13].”
BackgroundMa, T., Yang, H., & Lu, L. (2014) · Solar Energy · doi:10.1016/j.solener.2013.12.003 · Cited by 264 · cited 1×
“given in [25] are adopted, as manipulated in [26]:”
MethodA novel maximum power point tracking technique for solar panels using a SEPIC or Cuk converter
Chung, H. S.-H., Tse, K. K., Hui, S. Y. R., Mok, C. M., & Ho, M. T. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810841 · Cited by 237 · cited 2×
“4 two alternative approaches are examined: a triangular perturbation signal with a constant amplitude (green markers) as in [19], and adjustable”
BackgroundMethodLaudani, A., Riganti Fulginei, F., & Salvini, A. (2014) · Solar Energy · doi:10.1016/j.solener.2014.02.014 · Cited by 233 · cited 2×
“the theoretical investigation of [30], which concludes that only two of the five parameters are really independent.”
Background
Cited by
Grid-Forming Inverters: A Critical Asset for the Power Grid
Lasseter, R. H., Chen, Z., & Pattabiraman, D. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2959271 · Cited by 864
A review of energy storage technologies for large scale photovoltaic power plants
Bullich-Massagué, E., Cifuentes-García, F.-J., Glenny-Crende, I., Cheah-Mañé, M., Aragüés-Peñalba, M., Díaz-González, F., & Gomis-Bellmunt, O. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.115213 · Cited by 214
Haghighat, M., Niroomand, M., Dehghani Tafti, H., D. Townsend, C., & Fernando, T. (2024) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2022.000845 · Cited by 30
Metadata
- Authors
- Batzelis, E. I., Kampitsis, G. E., & Papathanassiou, S. A.
- Venue
- IEEE Transactions on Sustainable Energy
- Published
- 2017-07
- Volume
- 8
- Issue
- 3
- Pages
- 1269-1280
- ISSN
- 1949-3029 (ISSN-L)
- 1949-3037
- OpenAlex
- W2589414915
- Cited by
- 191
- References
- 20
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.