Load Frequency Control in Microgrids Based on a Stochastic Noninteger Controller
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this paper, an adaptive multiobjective fractional-order fuzzy proportional-integral-derivative controller is proposed for the load frequency control (LFC) of islanded microgrids (MGs), while benefiting from the assets of electric vehicles (EVs) in this respect. Although the use of battery energy storage systems (BESS) can solve the unbalance effects between the load and supply of an isolated MG, their high cost and tendency toward degradation are restrictive factors, which call for the use of alternative power balancing options. In recent years, the concept of utilizing the BESSs of EVs, also known as vehicle-to-grid (V2G) concept, for frequency support of MGs has attracted a lot of attention. In order to allow the V2G controller operate optimally under a wide range of operation conditions caused by the intermittent behavior of renewable energy resources, a new multiobjective fractional-order control strategy for the EVs in V2G scenarios is proposed in this paper. Moreover, since the performance of the controller depends on its parameters, optimization of these parameters can play a significant role in promoting the output performance of the LFC control; hence, a modified black hole optimization algorithm is utilized for the adaptive tuning of the noninteger fuzzy PID controller coefficients. The performance of the proposed LFC is evaluated by using real world wind and solar radiation data. Finally, the extensive studies and hardware-in-the-loop simulations are presented to prove that the proposed controller tracks frequency with lower deviation and fluctuation and is more robust in comparison with the prior-art controllers used in all the case studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geometric Type-1 and Type-2 Fuzzy Logic Systems
Coupland, S., & John, R. (2007) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2006.889764 · Cited by 316
Cited by
Microgrid control: A comprehensive survey
Sen, S., & Kumar, V. (2018) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2018.04.012 · Cited by 228
Lu, K., Zhou, W., Zeng, G., & Zheng, Y. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2018.08.043 · Cited by 189
Latif, A., Hussain, S. M. S., Das, D. C., & Ustun, T. S. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.114858 · Cited by 183
Banol Arias, N., Hashemi, S., Andersen, P. B., Traeholt, C., & Romero, R. (2019) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2018.2889439 · Cited by 181
“In that case, the EV control for frequency regulation in microgrids could be also considered as a service for DSOs, since they have the potential to improve microgrid stability when operating in an isolated mode, as discussed in [42]–[45].”
Metadata
- Authors
- Khooban, M.-H., Niknam, T., Shasadeghi, M., Dragicevic, T., & Blaabjerg, F.
- Venue
- IEEE Transactions on Sustainable Energy
- Published
- 2018-04
- Volume
- 9
- Issue
- 2
- Pages
- 853-861
- ISSN
- 1949-3029 (ISSN-L)
- 1949-3037
- OpenAlex
- W2765551348
- Cited by
- 231
- References
- 1
- FWCI
- 9.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.