The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Adaptive Capacity Provisioning for Carbon-Aware Data Centers: A Digital Twin-Based Approach
Abstract
This paper considers the carbon-aware data center (DC) capacity provisioning problem under uncertain green energy availability and computing demand. To address it, accurate carbon emissions estimation and robust capacity provisioning are necessary. Existing studies mainly consider the carbon footprint of the computing system and merely consider that of the physical facilities, which also contribute significant carbon emissions. Furthermore, their capacity provisioning is neither uncertainty-aware nor adaptive to the dynamic computing demand. To bridge these gaps, we propose an adaptive capacity provisioning framework based on the physics-informed digital twin. We design the digital twin to holistically capture a DC's operational carbon footprint, including both the computing system and the physical facilities. The digital twin is differentiable and established with a collection of physics-informed learnable models that are learned with online operational data. We further address the challenge of capacity provisioning under uncertainties by designing a shrinking horizon model predictive control. The designed capacity planner updates its estimation of future computing demand based on the observable computing system states. At each capacity provisioning round, we solve the capacity provisioning problem using a gradient-based optimization technique with the gradient provided by the digital twin. We extensively evaluate our approach usingrealoperational data from a large-scale production data center. First, our digital twin accurately predicts holistic DC energy usage with a relative absolute error of less than 5%, which is accurate according to the industrial rule of thumb. Second, we show that our solution is comparable to the oracle solution with perfect knowledge about all uncertainties, outperforming the state-of-the-art Predict-then-Plan approach significantly in terms of SLO violation reduction. Furthermore, our approach reduces carbon footprint by 27% compared with the over-provisioning scheme currently adopted by the industry.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318 · cited 1×
“Then, the output of the Poisson arrival model is combined with the temporal features to the resource model to predict the resource request of each workload with a long short-term memory (LSTM) model [38].”
PyTorch: An Imperative Style, High-Performance Deep Learning Library
Paszke, A., Gross, S., Massa, F., Lerer, A., Bradbury, J., Chanan, G., Killeen, T., Lin, Z., Gimelshein, N., Antiga, L., et al. (2019) · arXiv · doi:10.48550/arxiv.1912.01703 · Cited by 31,473 · cited 2×
“Furthermore, we implement our digital twin using Pytorch [33] to make it differentiable with respect to its inputs and internal parameters.”
EnergyPlus: creating a new-generation building energy simulation program
Crawley, D. B., Lawrie, L. K., Winkelmann, F. C., Buhl, W. F., Huang, Y. J., Pedersen, C. O., Strand, R. K., Liesen, R. J., Fisher, D. E., Witte, M. J., et al. (2001) · Energy and Buildings · doi:10.1016/s0378-7788(00)00114-6 · Cited by 2,822 · cited 4×
“Some latest works adopt sophisticated physics-based energy simulators (e.g., EnergyPlus [7]) to evaluate DC energy footprint.”
InfluentialDeepAR: Probabilistic forecasting with autoregressive recurrent networks
Salinas, D., Flunkert, V., Gasthaus, J., & Januschowski, T. (2020) · International Journal of Forecasting · doi:10.1016/j.ijforecast.2019.07.001 · Cited by 2,661
Stochastic Network Optimization with Application to Communication and Queueing Systems
Neely, M. J. (2010) · Synthesis lectures on communication networks · doi:10.2200/s00271ed1v01y201006cnt007 · Cited by 2,218
Making scheduling cool: temperature-aware workload placement in data centers
Moore, J., Chase, J., Ranganathan, P., & Sharma, R. K. (2005) · USENIX Annual Technical Conference · Cited by 651
Cortez, E., Bonde, A., Muzio, A., Russinovich, M., Fontoura, M., & Bianchini, R. (2017) · Proceedings of the 26th Symposium on Operating Systems Principles · doi:10.1145/3132747.3132772 · Cited by 633 · cited 1×
“We use publicly available cloud workload trace from Azure [42] in our evaluation.”
Kouvaritakis, B., & Cannon, M. (2016) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-3-319-24853-0 · Cited by 515
Renewable and cooling aware workload management for sustainable data centers
Liu, Z., Chen, Y., Bash, C., Wierman, A., Gmach, D., Wang, Z., Marwah, M., & Hyser, C. (2012) · Proceedings of the 12th ACM SIGMETRICS/PERFORMANCE joint international conference on Measurement and Modeling of Computer Systems · doi:10.1145/2254756.2254779 · Cited by 413
Self-citationCarbon-aware computing for datacenters
Radovanović, A., Koningstein, R., Schneider, I., Chen, B., Duarte, A., Roy, B., Xiao, D., Haridasan, M., Hung, P., Care, N., et al. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3173250 · Cited by 353 · cited 9×
“In this paper, we focus on the power modeling of the aggregated computing demand similar to the previous work [5], [12].”
Influential
Research works printed but not linked: 4
- Shafto, 2012, Modeling, simulation, information technology & processing roadmap, Nat. Aeronaut. Space Admin., 32, 1
- Bergman, 2011, Fundamentals of Heat and Mass Transfer
- 2022, Energy transformation (chapter 2)
- Guideline, 2014, Measurement of energy, demand, and water savings, ASHRAE Guideline, 4, 1
Cited by
Kim, J., Kim, J., Sovacool, B. K., Griffiths, S., Bazilian, M., Creutzig, F., Rio, D. D. F. D., Agarwala, M., Choi, M., & Debnath, R. (2026) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2026.116861 · Cited by 27
Alex, M., Ojo, S. O., & Awuor, F. M. (2025) · Computers · doi:10.3390/computers14070280 · Cited by 22
Bytes for beaks? The green transformation of data center and bird biodiversity in China
Liang, Y., Han, X., & Kai, Z. (2025) · Finance research letters · doi:10.1016/j.frl.2025.108564 · Cited by 9
Wang, J., Cao, S., Li, R., & Xu, W. (2025) · Energies · doi:10.3390/en18215741 · Cited by 7
Chen, J., Al-Nussairi, A. K. J., Chyad, M. H., Azarinfar, H., Khosravi, M., Jin, K., & Zhang, J. (2025) · Energy Reports · doi:10.1016/j.egyr.2025.03.052 · Cited by 7
Metadata
- Authors
- Cao, Z., Wang, R., Zhou, X., Tan, R., Wen, Y., Yan, Y., & Wang, Z.
- Affiliations
- Nanyang Technological University (SG)
- Jiangxi Science and Technology Normal University (CN)
- Alibaba Group (China) (CN)
- Venue
- IEEE Transactions on Sustainable Computing
- Published
- 2025-07
- Volume
- 10
- Issue
- 4
- Pages
- 730-743
- ISSN
- 2377-3782 (ISSN-L)
- 2377-3790
- OpenAlex
- W4406321541
- Cited by
- 16
- References
- 45
- Citations by year
- 2026: 9 · 2025: 7
- FWCI
- 16.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Sustainable Computing (publishedVersion)
- DR-NTU (Nanyang Technological University) (submittedVersion)
- Funders
- RIE2025 Industry Alignment Fund
- Industry Collaboration Projects (I2301E0026)
- Alibaba Group
- Nanyang Technological University
- National Natural Science Foundation of China (62262026)
- Natural Science Foundation of Jiangxi Province (20232BAB202020)
- Topics
- Physical Sciences › Computer Science › Information Systems › Cloud Computing and Resource Management
- Physical Sciences › Computer Science › Hardware and Architecture › Energy Efficiency in Computing
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Green IT and Sustainability
- Keywords
- capacity provisioning, digital twin, physics-informed neural networks, carbon footprint calculation, model predictive control, energy usage prediction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adaptive Capacity Provisioning for Carbon-Aware Data Centers: A Digital Twin-Based Approach. https://app.cochat.ai/papers/10.1109/tsusc.2025.3526192
- The paper
- Cao, Z., Wang, R., Zhou, X., Tan, R., Wen, Y., Yan, Y., & Wang, Z. (2025). Adaptive Capacity Provisioning for Carbon-Aware Data Centers: A Digital Twin-Based Approach. IEEE Transactions on Sustainable Computing. https://doi.org/10.1109/tsusc.2025.3526192
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.