Time-delay estimation (TDE) is a common operation in ultrasound signal processing. In applications such as blood flow estimation, elastography, phase aberration correction, and many more, the quality of final results is heavily dependent upon the performance of the time-delay estimator implemented. In the past years, several algorithms have been developed and applied in medical ultrasound, sonar, radar, and other fields. In this paper we analyze the performances of the widely used normalized and non-normalized correlations, along with normalized covariance, sum absolute differences (SAD), sum squared differences (SSD), hybrid-sign correlation, polarity-coincidence correlation, and the Meyr-Spies method. These techniques have been applied to simulated ultrasound radio frequency (RF) data under a variety of conditions. We show how parameters, which include center frequency, fractional bandwidth, kernel window size, signal decorrelation, and signal-to-noise ratio (SNR) affect the quality of the delay estimate. Simulation results also are compared with a theoretical performance limit set by the Cramér-Rao lower bound (CRLB). Results show that, for high SNR, high signal correlation, and large kernel size, all of the algorithms closely match the theoretical bound, with relative performances that vary by as much as 20%. As conditions degrade, the performances of various algorithms differ more significantly. For signals with a correlation level of 0.98, SNR of 30 dB, center frequency of 5 MHz with a fractional bandwidth of 0.5, and kernel size of 2 micros, the standard deviation of the jitter error is on the order of few nanoseconds. Normalized correlation, normalized covariance, and SSD have an approximately equal jitter error of 2.23 ns (the value predicted by the CRLB is 2.073 ns), whereas the polarity-coincidence correlation performs less well with a jitter error of 2.74 ns.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tuffc.2003.1197962

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 233

Metadata

Authors
Viola, F., & Walker, W. F.
Venue
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
Published
2003-04
Volume
50
Issue
4
Pages
392-401
ISSN
0885-3010 (ISSN-L)
OpenAlex
W2142271048
Cited by
233
References
0
FWCI
5.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A comparison of the performance of time-delay estimators in medical ultrasound. https://app.cochat.ai/papers/10.1109/tuffc.2003.1197962
The paper
Viola, F., & Walker, W. F. (2003). A comparison of the performance of time-delay estimators in medical ultrasound. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. https://doi.org/10.1109/tuffc.2003.1197962

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.