The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Omni-directional guided wave transducer arrays for the rapid inspection of large areas of plate structures
Abstract
Omni-directional guided wave array transducers contain a circular pattern of elements that individually behave as omni-directional point transmitters or receivers. The data set acquired from such an array contains time-domain signals from each permutation of transmitter and receiver. A phased addition algorithm is developed that allows an omni-directional, B-scan image of the surrounding plate to be synthesized from any geometry of array. Numerically simulated data from a single reflector is used to test the performance of the algorithm. The results from an array containing a fully populated circular area of elements (Type I array) are found to be good, but those from an array containing a single ring of elements (Type II array) contain many large side-lobes. An enhancement to the basic-phased addition algorithm is presented that uses deconvolution to suppress these side-lobes. The deconvolution algorithm enables a Type II array to equal the performance of a Type I array of the same overall diameter. The effect of diameter on angular resolution is investigated. Experimental data obtained from a guided wave array containing electromagnetic acoustic transducers (EMAT) elements for exciting and detecting the So Lamb wave mode in a 5-mm thick aluminium plate are processed with both algorithms and the results are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Discrete-Time Signal Processing
Oppenheim, A. V., & Schafer, R. W. (1989) · Cited by 12,566
A rapid signal processing technique to remove the effect of dispersion from guided wave signals
Wilcox, P. D. (2003) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1197965 · Cited by 400
Self-citationThe effect of dispersion on long-range inspection using ultrasonic guided waves
Wilcox, P., Lowe, M., & Cawley, P. (2001) · NDT & E International · doi:10.1016/s0963-8695(00)00024-4 · Cited by 316
Self-citation
Cited by
Ultrasonic Guided Waves in Solid Media
Rose, J. L. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9781107273610 · Cited by 1,496
Ultrasonic arrays for non-destructive evaluation: A review
Drinkwater, B. W., & Wilcox, P. D. (2006) · NDT & E International · doi:10.1016/j.ndteint.2006.03.006 · Cited by 1,147
Self-citationIn situ 2-D piezoelectric wafer active sensors arrays for guided wave damage detection
Yu, L., & Giurgiutiu, V. (2008) · Ultrasonics · doi:10.1016/j.ultras.2007.10.008 · Cited by 315
Guided wave signal processing and image fusion for in situ damage localization in plates
Michaels, J. E., & Michaels, T. E. (2007) · Wave Motion · doi:10.1016/j.wavemoti.2007.02.008 · Cited by 298
Mustapha, S., Lu, Y., Ng, C.-T., & Malinowski, P. (2021) · Vibration · doi:10.3390/vibration4030033 · Cited by 84
Metadata
- Authors
- Wilcox, P. D.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 2003-06
- Volume
- 50
- Issue
- 6
- Pages
- 699-709
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2137011497
- Cited by
- 271
- References
- 3
- FWCI
- 7.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.