Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 213

The DOI matches its Crossref record.

Propagation of spontaneously actuated pulsive vibration in human heart wall and in vivo viscoelasticity estimation

Open access
Kanai, H.·2005·IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control

Abstract

Though myocardial viscoelasticity is essential in the evaluation of heart diastolic properties, it has never been noninvasively measured in vivo. By the ultrasonic measurement of the myocardial motion, we have already found that some pulsive waves are spontaneously excited by aortic-valve closure (AVC) at end-systole (T0). These waves may serve as an ideal source of the intrinsic heart sound caused by AVC. In this study, using a sparse sector scan, in which the beam directions are restricted to about 16, the pulsive waves were measured almost simultaneously at about 160 points set along the heart wall at a sufficiently high frame rate. The consecutive spatial phase distributions, obtained by the Fourier transform of the measured waves, clearly revealed wave propagation along the heart wall for the first time. The propagation time of the wave along the heart wall is very small (namely, several milliseconds) and cannot be measured by conventional equipment. Based on this phenomenon, we developed a means to measure the myocardial viscoelasticity in vivo. In this measurement, the phase velocity of the wave is determined for each frequency component. By comparing the dispersion of the phase velocity with the theoretical one of the Lamb wave (the plate flexural wave), which propagates along the viscoelastic plate (heart wall) immersed in blood, the instantaneous viscoelasticity is determined noninvasively. This is the first report of such noninvasive determination. In in vivo experiments applied to five healthy subjects, propagation of the pulsive wave was clearly visible in all subjects. For the 60-Hz component, the typical propagation speed rapidly decreased from 5 m/s just before the time of AVC (t = T0 - 8 ms) to 3 m/s at t = T0 + 10 ms. In the experiments, it was possible to determine the viscosity more precisely than the elasticity. The typical value of elasticity was about 24-30 kPa and did not change around the time of AVC. The typical transient values of viscosity decreased rapidly from 400 Pa x s at t = T0 - 8 ms to 70 Pa x s at t = T0 + 10 ms. The measured shear elasticity and viscosity in this study are comparable to those obtained for the human tissues using audio frequency in in vitro experiments reported in the literature.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tuffc.2005.1561662

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 213

Metadata

Authors
Kanai, H.
Venue
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
Published
2005-11
Volume
52
Issue
11
Pages
1931-1942
ISSN
0885-3010 (ISSN-L)
OpenAlex
W2105448221
Cited by
213
References
0
FWCI
4.29
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Propagation of spontaneously actuated pulsive vibration in human heart wall and in vivo viscoelasticity estimation. https://app.cochat.ai/papers/10.1109/tuffc.2005.1561662
The paper
Kanai, H. (2005). Propagation of spontaneously actuated pulsive vibration in human heart wall and in vivo viscoelasticity estimation. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. https://doi.org/10.1109/tuffc.2005.1561662

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.