The DOI matches its Crossref record.
Evaluation of the damage detection capability of a sparse-array guided-wave SHM system applied to a complex structure under varying thermal conditions
Abstract
A sparse-array structural health monitoring (SHM) system based on guided waves was applied to the door of a commercial shipping container. The door comprised a corrugated steel panel approximately 2.4 m by 2.4 m surrounded by a box beam frame and testing was performed in a nonlaboratory environment. A 3-D finite element (FE) model of the corrugations was used to predict transmission coefficients for the A0 and S0 modes across the corrugations as a function of incidence angle. The S0 mode transmission across the corrugations was substantially stronger, and this mode was used in the main test series. A sparse array with 9 transducers was attached to the structure, and signals from the undamaged structure were recorded at periodic intervals over a 3-week period, and the resulting signal database was used for temperature compensation of subsequent signals. Defects in the form of holes whose diameter was increased incrementally from 1 to 10 mm were introduced at 2 different points of the structure, and signals were taken for each condition. Direct analysis of subtracted signals allowed understanding of the defect detection capability of the system. Comparison of signals transmitted between different transducer pairs before and after damage was used to give an initial indication of defect detectability. Signals from all combinations of transducers were then used in imaging algorithms, and good localization of holes with a 5-mm diameter or above was possible within the sparse array, which covered half of the area of the structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Schubert, K. J., Brauner, C., & Herrmann, A. S. (2014) · Structural Health Monitoring · doi:10.1177/1475921713513975 · Cited by 37
Metadata
- Authors
- Clarke, T., Cawley, P., Wilcox, P. D., & Croxford, A. J.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 2009-12
- Volume
- 56
- Issue
- 12
- Pages
- 2666-2678
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2139191728
- Cited by
- 158
- References
- 0
- FWCI
- 12.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the damage detection capability of a sparse-array guided-wave SHM system applied to a complex structure under varying thermal conditions. https://app.cochat.ai/papers/10.1109/tuffc.2009.1357
- The paper
- Clarke, T., Cawley, P., Wilcox, P. D., & Croxford, A. J. (2009). Evaluation of the damage detection capability of a sparse-array guided-wave SHM system applied to a complex structure under varying thermal conditions. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. https://doi.org/10.1109/tuffc.2009.1357
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.