Asymmetrical Multilevel Inverter for Traction Drives Using Only One DC Supply
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
The main advantage of asymmetrical multilevel inverters is the optimization of levels with a minimum number of power supplies. However, this optimized multilevel system still needs a large number of isolated and floating dc supplies, which makes these converters complicated to implement in electric vehicles (EVs), because the system will require many independent battery packs. In this paper, a very simple scheme, based on a small and cheap high-frequency link (HFL), allows the utilization of only one power supply for the complete multilevel inverter drive, with an inherent regulation of the voltages supplied among the H-bridges. It also allows voltage control with the full number of levels if the dc source is of a variable voltage characteristic. This paper is focused on a 27-level asymmetric inverter, but the strategy, using only one power supply, can be applied to converters with any number of levels. In particular, an asymmetrical 27-level converter needs nine isolated power supplies, and the proposed system reduces these nine sources to only one: the battery car. The topology also permits full regenerative braking working as a three-level converter. The proposed system is intended for application in EVs from power ratings up to 150 kW. Simulations and experimental results show the feasibility to implement this “one-source” multilevel system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Survey on Cascaded Multilevel Inverters
Malinowski, M., Gopakumar, K., Rodriguez, J., & Pérez, M. A. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030767 · Cited by 2,322 · cited 1×
“I. INTRODUCTION TODAY, cascade multilevel converters have become verypopular, because they are able to generate voltage waveforms with negligible distortion when compared with conventional inverters based on two- or three-level topologies [1]– [3].”
BackgroundThe age of multilevel converters arrives
Franquelo, L., Rodriguez, J., Leon, J., Kouro, S., Portillo, R., & Prats, M. (2008) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2008.923519 · Cited by 2,016
Hybrid multilevel power conversion system: a competitive solution for high-power applications
Manjrekar, M. D., Steimer, P. K., & Lipo, T. A. (2000) · IEEE Transactions on Industry Applications · doi:10.1109/28.845059 · Cited by 739
Du, Z., Ozpineci, B., Tolbert, L. M., & Chiasson, J. N. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2018978 · Cited by 256 · cited 1×
“Other solutions using cascaded multilevel inverters with a single power source and without transformers have been introduced recently [14]–[16].”
BackgroundCascaded Multilevel Inverter Employing Three-Phase Transformers and Single DC Input
Song, S. G., Kang, F. S., & Park, S.-J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2013846 · Cited by 167 · cited 1×
“In applications with constant frequency operation, such as power rectifiers, active power filters, or flexible ac transmission systems, output power transformers are used to connect the load, allowing operation with only one dc supply [10]–[12].”
MethodDC-Voltage-Ratio Control Strategy for Multilevel Cascaded Converters Fed With a Single DC Source
Vázquez, S., Leon, J. I., Franquelo, L. G., Padilla, J. J., & Carrasco, J. M. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2017549 · Cited by 155
High-level multistep inverter optimization using a minimum number of power transistors
Dixon, J., & Moran, L. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.869745 · Cited by 145 · cited 1×
“One step ahead was the asymmetrical multilevel converter, which allows the generation of many more levels of voltage with a minimum number of power supplies [4]–[6].”
BackgroundSelf-citationSynthesis of Multilevel Converters Based on Single- and/or Three-Phase Converter Building Blocks
Wen, J. X., & Smedley, K. M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921175 · Cited by 138 · cited 1×
“I. INTRODUCTION TODAY, cascade multilevel converters have become verypopular, because they are able to generate voltage waveforms with negligible distortion when compared with conventional inverters based on two- or three-level topologies [1]– [3].”
BackgroundPower Distribution in Hybrid Multi-cell Converter with Nearest Level Modulation
Perez, M., Rodriguez, J., Pontt, J., & Kouro, S. (2007) · 2007 IEEE International Symposium on Industrial Electronics · doi:10.1109/isie.2007.4374688 · Cited by 131 · cited 1×
“During regeneration, the system works as a three-level inverter, but this is not a big 0018-9545/$26.00 © 2010 IEEE drawback because regenerative braking is normally used for short periods.”
BackgroundInfluentialRotella, M., Penailillo, G., Pereda, J., & Dixon, J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.927233 · Cited by 89 · cited 4×
“For example, at 55% output power, the Aux-1 bridge has 15% negative power, as shown in Fig.”
BackgroundMethodSelf-citationBarriuso, P., Dixon, J., Flores, P., & Moran, L. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005680 · Cited by 70 · cited 1×
“In applications with constant frequency operation, such as power rectifiers, active power filters, or flexible ac transmission systems, output power transformers are used to connect the load, allowing operation with only one dc supply [10]–[12].”
MethodSelf-citationA transformerless battery energy storage system based on a multilevel cascade PWM converter
Maharjan, L., Inoue, S., Akagi, H., & Asakura, J. (2008) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2008.4592732 · Cited by 62 · cited 1×
“Another drawback is the direct relation between the number of levels and the voltage amplitude, which produce a loss of quality when the output voltage is reduced.”
Background
Cited by
Bana, P. R., Panda, K. P., Naayagi, R. T., Siano, P., & Panda, G. (2019) · IEEE Access · doi:10.1109/access.2019.2913447 · Cited by 361
Power Quality Issues in Railway Electrification: A Comprehensive Perspective
Mousavi Gazafrudi, S. M., Tabakhpour Langerudy, A., Fuchs, E. F., & Al-Haddad, K. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2386794 · Cited by 340
Salem, A., Van Khang, H., Robbersmyr, K. G., Norambuena, M., & Rodriguez, J. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3011908 · Cited by 285
Kazmierkowski, M., Franquelo, L., Rodriguez, J., Perez, M., & Leon, J. (2011) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2011.942173 · Cited by 221
“In particular, the asymmetrical CHB converter, built using different values of the dc voltage for each power cell, allows to increase the number of output voltage levels using only a reduced number of power cells [30].”
MethodA New Multilevel Inverter Topology With Self-Balancing Level Doubling Network
Chattopadhyay, S. K., & Chakraborty, C. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2290751 · Cited by 184
“While most of the power is delivered by the highest voltage cell [6], the lower voltage cells deal with only a fraction of the same.”
Background
Metadata
- Authors
- Dixon, J., Pereda, J., Castillo, C., & Bosch, S.
- Venue
- IEEE Transactions on Vehicular Technology
- Published
- 2010-10
- Volume
- 59
- Issue
- 8
- Pages
- 3736-3743
- ISSN
- 0018-9545 (ISSN-L)
- 1939-9359
- OpenAlex
- W2155793039
- Cited by
- 165
- References
- 12
- FWCI
- 8.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.