CoChat

High Efficiency Integrated Transformer Design in DAB Converters for Solid-State Transformers

Lee, Eun S., Park, Jin H., Kim, Myung Y., Lee, June S. · 2022 · IEEE Transactions on Vehicular Technology

The DOI matches its Crossref record; the references it cites are not checked yet.

Abstract

Solid-state transformers (SST) are emerging technologies to replace the conventional low-frequency main transformer (MTR) in railway vehicles. In order to isolate the load side from the AC 25 kV high-voltage (HV) side and to reduce the whole size of the SST, HV insulation and high-frequency transformers should be used in DC/DC converters. Furthermore, due to the severe constraint of installation space and difficulty of heat dissipation management in the bottom of railway vehicles, high-power density and minimum transformer loss should be considered. To satisfy such design requirements of the proposed SST for railway vehicles, high efficiency integrated transformers, which inherently have leakage inductance, are proposed for dual-active-bridge (DAB) converters in this paper. In order to obtain appropriate equivalent leakage inductance for the DAB converters, a calculation methodology for the leakage inductance has been introduced and verified by simulation. Two separated winding structures in the center-core are adopted to improve the core loss, and appropriate winding turns with 60 kV HV insulation capability are selected, according to the proposed design procedure of the integrated transformers. In order to compare the proposed transformers with the conventional transformer having additional inductors and to verify the major characteristics of the transformers, two 125 kW proposed transformers and conventional transformers have been built and evaluated by an 250 kW SST modul…

Overview

Integrity signals

Registry

Crossref · 10.1109/tvt.2022.3168561

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

The citation lists are queued

They are fetched later and appear here then.

References 25 · Cited by 63

Research works printed but not linked: 2

  1. Cougo, Integration of leakage inductance in tape wound core transformers for dual active bridge converters, 1
  2. 2017, National Fire Protection Association (NFPA)

Metadata

Authors
Lee, E. S., Park, J. H., Kim, M. Y., & Lee, J. S.
Affiliations
  • Hanyang University (KR)
  • Korea Railroad Research Institute (KR)
  • Dankook University (KR)
Venue
IEEE Transactions on Vehicular Technology
Published
2022-07
Volume
71
Issue
7
Pages
7147-7160
ISSN
  • 0018-9545 (ISSN-L)
  • 1939-9359
OpenAlex
W4226271985
Cited by
63
References
25
Citations by year
2026: 12 · 2025: 19 · 2024: 14 · 2023: 15 · 2022: 3
FWCI
3.49
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Vehicular Technology (publishedVersion)
Funders
  • Railroad Technology Development Program
  • Ministry of Land, Infrastructure and Transport (21RSCD-C163337-01)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
Keywords
solid-state transformer, dual active bridge converter, integrated transformer, leakage inductance, DC-DC converter, high-voltage insulation, transformer efficiency, core loss, transformer size reduction, heat dissipation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High Efficiency Integrated Transformer Design in DAB Converters for Solid-State Transformers. https://app.cochat.ai/papers/10.1109/tvt.2022.3168561
The paper
Lee, E. S., Park, J. H., Kim, M. Y., & Lee, J. S. (2022). High Efficiency Integrated Transformer Design in DAB Converters for Solid-State Transformers. IEEE Transactions on Vehicular Technology. https://doi.org/10.1109/tvt.2022.3168561

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.