UWB for noninvasive wireless body area networks: channel measurements and results
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The paper presents UWB channel measurements from 3 to 6 GHz for a body area network (BAN) in an anechoic chamber and an office room. Both, transmit and receive antenna were placed directly on the body. Channel parameters as delay spread and path loss are extracted from the measurements and the influence of the body is highlighted. We show that in some situations there are significant echoes from the body (e.g. from the arms) and we observed deterministic echoes from the floor that could help to simplify a RAKE receiver structure. Finally, we consider the overall energy consumption of the BAN and give decision regions for singlehop and multihop links in relation to signal processing energy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Mobile Radio Propagation Channel
Parsons, J. D. (2001) · Wiley eBooks · doi:10.1002/0470841524 · Cited by 1,180
Ultra-wideband radio technology: Potential and challenges ahead
Porcino, D., & Hirt, W. (2003) · IEEE Communications Magazine · doi:10.1109/mcom.2003.1215641 · Cited by 979
On the energy capture of ultrawide bandwidth signals in dense multipath environments
Win, M. Z., & Scholtz, R. A. (1998) · IEEE Communications Letters · doi:10.1109/4234.718491 · Cited by 514
Staderini, E. M. (2002) · IEEE Aerospace and Electronic Systems Magazine · doi:10.1109/62.978359 · Cited by 496
Cited by
Wireless Body Area Networks: A Survey
Movassaghi, S., Abolhasan, M., Lipman, J., Smith, D., & Jamalipour, A. (2014) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2013.121313.00064 · Cited by 1,538
A survey on wireless body area networks
Latré, B., Braem, B., Moerman, I., Blondia, C., & Demeester, P. (2011) · Wireless Networks · doi:10.1007/s11276-010-0252-4 · Cited by 1,099
A Comprehensive Survey of Wireless Body Area Networks: On PHY, MAC, and Network Layers Solutions
Ullah, S., Higgins, H., Braem, B., Latre, B., Blondia, C., Moerman, I., Saleem, S., Rahman, Z., & Kwak, K. S. (2012) · Journal of Medical Systems · doi:10.1007/s10916-010-9571-3 · Cited by 811
“In [51], a first attempt is done to justify the use of multi-hop in WBAN, where intermediate hops are used for reaching the receiver.”
BackgroundUltrawideband Propagation Channels-Theory, Measurement, and Modeling
Molisch, A. F. (2005) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2005.856194 · Cited by 747
A Comprehensive Standardized Model for Ultrawideband Propagation Channels
Molisch, A. F., Cassioli, D., Chong, C.-C., Emami, S., Fort, A., Kannan, B., Karedal, J., Kunisch, J., Schantz, H. G., Siwiak, K., et al. (2006) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2006.883983 · Cited by 719
Metadata
- Authors
- Zasowski, T., Althaus, F., Stager, M., Wittneben, A., & Troster, G.
- Venue
- IEEE Conference on Ultra Wideband Systems and Technologies, 2003
- Publisher
- IEEE
- Published
- 2004-07-08
- Pages
- 285-289
- OpenAlex
- W2534345316
- Cited by
- 255
- References
- 4
- FWCI
- 36.85
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.