The Fully Convolutional Transformer for Medical Image Segmentation
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
We propose a novel transformer, capable of segmenting medical images of varying modalities. Challenges posed by the fine-grained nature of medical image analysis mean that the adaptation of the transformer for their analysis is still at nascent stages. The overwhelming success of the UNet lay in its ability to appreciate the fine-grained nature of the segmentation task, an ability which existing transformer based models do not currently posses. To address this shortcoming, we propose The Fully Convolutional Transformer (FCT), which builds on the proven ability of Convolutional Neural Networks to learn effective image representations, and combines them with the ability of Transformers to effectively capture long-term dependencies in its inputs. The FCT is the first fully convolutional Transformer model in medical imaging literature. It processes its input in two stages, where first, it learns to extract long range semantic dependencies from the input image, and then learns to capture hierarchical global attributes from the features. FCT is compact, accurate and robust. Our results show that it outperforms all existing transformer architectures by large margins across multiple medical image segmentation datasets of varying data modalities without the need for any pre-training. FCT outperforms its immediate competitor on the ACDC dataset by 1.3%, on the Synapse dataset by 4.4%, on the Spleen dataset by 1.2% and on ISIC 2017 dataset by 1.1% on the dice metric, with up to five times fewer parameters. On the ACDC Post-2017-MICCAI-Challenge online test set, our model sets a new state-of-the-art on unseen MRI test cases out-performing large ensemble models as well as nnUNet with considerably fewer parameters. Our code, environments and models will be available via GitHub†.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Exploiting Generative AI to Scale up Intelligent Tutoring Systems
Jakubův, J., Chvalovský, K., Goertzel, Z., Kaliszyk, C., Olšák, M., Piotrowski, B., Schulz, S., Suda, M., & Urban, J. (2023) · DROPS (Schloss Dagstuhl – Leibniz Center for Informatics) · doi:10.4230/lipics.itp.2023.19 · Cited by 76,658
An Image is Worth 16x16 Words: Transformers for Image Recognition at Scale
Dosovitskiy, A., Beyer, L., Kolesnikov, A., Weissenborn, D., Zhai, X., Unterthiner, T., Dehghani, M., Minderer, M., Heigold, G., Gelly, S., et al. (2020) · arXiv · doi:10.48550/arxiv.2010.11929 · Cited by 47,472 · cited 7×
“Transformer models: The original Transformer architecture [31] revolutionized natural language processing tasks and has quickly become the de-facto model for visual understanding tasks as well [7].”
BackgroundMethodInfluentialSwin Transformer: Hierarchical Vision Transformer using Shifted Windows
Liu, Z., Lin, Y., Cao, Y., Hu, H., Wei, Y., Zhang, Z., Lin, S., & Guo, B. (2021) · 2021 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv48922.2021.00986 · Cited by 35,534 · cited 5×
“Recently proposed architectures such as ViT [7] have surpassed the performance of CNNs on benchmark imaging tasks, and many recent improvements to ViT such as CvT [31], CCT [8] and Swin Transformer [21] have shown how transformers do not need to be bulky, data hungry models, and can even work with small amounts of dat…”
BackgroundInfluentialnnU-Net: a self-configuring method for deep learning-based biomedical image segmentation
Isensee, F., Jaeger, P. F., Kohl, S. A. A., Petersen, J., & Maier-Hein, K. H. (2021) · Nature Methods · doi:10.1038/s41592-020-01008-z · Cited by 10,477 · cited 1×
“Of the most influential UNet variants of recent times, the nnUNet [14] automatically adapts itself to pre-process the data and select the optimal network architecture that would be best suited to the task without the need for manual intervention.”
MethodUNet++: A Nested U-Net Architecture for Medical Image Segmentation
Zhou, Z., Rahman Siddiquee, M. M., Tajbakhsh, N., & Liang, J. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-00889-5_1 · Cited by 9,610
Swin-Unet: Unet-like pure transformer for medical image segmentation
Cao, H., Wang, Y., Chen, J., Jiang, D., Zhang, X., Tian, Q., & Wang, M. (2023) · Lecture Notes in Computer Science · doi:10.1007/978-3-031-25066-8_9 · Cited by 5,640
Attention U-Net: Learning Where to Look for the Pancreas
Oktay, O., Schlemper, J., Folgoc, L. L., Lee, M., Heinrich, M., Misawa, K., Mori, K., McDonagh, S., Hammerla, N. Y., Kainz, B., et al. (2018) · arXiv · doi:10.48550/arxiv.1804.03999 · Cited by 5,458 · cited 2×
“Similar to the Attention UNet [26], UNet Transformer [27] enhanced CNNs with multihead attention inside skip connections.”
TransUNet: Transformers Make Strong Encoders for Medical Image Segmentation
Chen, J., Lu, Y., Yu, Q., Luo, X., Adeli, E., Wang, Y., Lu, L., Yuille, A. L., & Zhou, Y. (2021) · arXiv · doi:10.48550/arxiv.2102.04306 · Cited by 4,206 · cited 4×
“We compare our results on the Synapse dataset mainly with TransUNet [5], LeViT-UNet [39] and Swin UNet [3] as we use the same splits and pre-processing as those models, which suggests that any increase in performance is due to the superiority of the proposed model.”
MethodResultInfluentialRethinking Semantic Segmentation from a Sequence-to-Sequence Perspective with Transformers
Zheng, S., Lu, J., Zhao, H., Zhu, X., Luo, Z., Wang, Y., Fu, Y., Feng, J., Xiang, T., Torr, P. H. S., et al. (2021) · 2021 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr46437.2021.00681 · Cited by 4,008 · cited 2×
“On Spleen segmentation we outperform recently proposed bench- mark models such as SETR [41], CoTr [38] and TransUNet [5] by over 1.2% dice with considerably fewer parameters.”
MethodInfluential
Cited by
A survey of the vision transformers and their CNN-transformer based variants
Khan, A., Rauf, Z., Sohail, A., Khan, A. R., Asif, H., Asif, A., & Farooq, U. (2023) · Artificial Intelligence Review · doi:10.1007/s10462-023-10595-0 · Cited by 451
ConvNextUNet: A small-region attentioned model for cardiac MRI segmentation
Zhang, H., & Cai, Z. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108592 · Cited by 17
Metadata
- Authors
- Tragakis, A., Kaul, C., Murray-Smith, R., & Husmeier, D.
- Venue
- 2023 IEEE/CVF Winter Conference on Applications of Computer Vision (WACV)
- Publisher
- IEEE
- Published
- 2023-01
- Pages
- 3649-3658
- OpenAlex
- W4319300365
- Cited by
- 164
- References
- 43
- FWCI
- 18.42
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Fully Convolutional Transformer for Medical Image Segmentation. https://app.cochat.ai/papers/10.1109/wacv56688.2023.00365
- The paper
- Tragakis, A., Kaul, C., Murray-Smith, R., & Husmeier, D. (2023). The Fully Convolutional Transformer for Medical Image Segmentation. 2023 IEEE/CVF Winter Conference on Applications of Computer Vision (WACV). https://doi.org/10.1109/wacv56688.2023.00365
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.