The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A comparison of Pedestrian Dead-Reckoning algorithms using a low-cost MEMS IMU
Abstract
Human localization is a very valuable information for smart environments. state-of-the-art local positioning systems (LPS) require a complex sensor-network infrastructure to locate with enough accuracy and coverage. Alternatively, inertial measuring units (IMU) can be used to estimate the movement of a person, by detecting steps, estimating stride lengths and the directions of motion; a methodology that is called pedestrian dead-reckoning (PDR). In this paper, we use low-performance microelectromechanical (MEMS) inertial sensors attached to the foot of a person. This sensor has triaxial orthogonal accelerometers, gyroscopes and magnetometers. We describe, implement and compare several of the most relevant algorithms for step detection, stride length, heading and position estimation. The challenge using MEMS is to provide location estimations with enough accuracy and a limited drift. Several tests were conducted outdoors and indoors, and we found that the stride length estimation errors were about 1%. The positioning errors were almost always below 5% of the total travelled distance. The main source of positioning errors are the absolute orientation estimation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pedestrian tracking using inertial sensors
Feliz Alonso, R., Zalama Casanova, E., & Gómez García-Bermejo, J. (2009) · Journal of Physical Agents (JoPha) · doi:10.14198/jopha.2009.3.1.05 · Cited by 228
Foot-to-Foot Range Measurement as an Aid to Personal Navigation
Brand, T., & Phillips, R. E. (2003) · Cited by 44
Cited by
A Survey of Indoor Inertial Positioning Systems for Pedestrians
Harle, R. (2013) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2012.121912.00075 · Cited by 814
Jimenez, A. R., Seco, F., Prieto, J. C., & Guevara, J. (2010) · 2010 7th Workshop on Positioning, Navigation and Communication · doi:10.1109/wpnc.2010.5649300 · Cited by 469
Self-citationAccurate Pedestrian Indoor Navigation by Tightly Coupling Foot-Mounted IMU and RFID Measurements
Jimenez Ruiz, A. R., Seco Granja, F., Prieto Honorato, J. C., & Guevara Rosas, J. I. (2012) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2011.2159317 · Cited by 446
WILL: Wireless Indoor Localization without Site Survey
Wu, C., Yang, Z., Liu, Y., & Xi, W. (2013) · IEEE Transactions on Parallel and Distributed Systems · doi:10.1109/tpds.2012.179 · Cited by 424
Smartphones Based Crowdsourcing for Indoor Localization
Wu, C., Yang, Z., & Liu, Y. (2015) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2014.2320254 · Cited by 383
Metadata
- Authors
- Jimenez, A. R., Seco, F., Prieto, C., & Guevara, J.
- Venue
- 2009 IEEE International Symposium on Intelligent Signal Processing
- Publisher
- IEEE
- Published
- 2009-08
- Pages
- 37-42
- OpenAlex
- W2122180522
- Cited by
- 575
- References
- 2
- FWCI
- 28.32
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison of Pedestrian Dead-Reckoning algorithms using a low-cost MEMS IMU. https://app.cochat.ai/papers/10.1109/wisp.2009.5286542
- The paper
- Jimenez, A. R., Seco, F., Prieto, C., & Guevara, J. (2009). A comparison of Pedestrian Dead-Reckoning algorithms using a low-cost MEMS IMU. 2009 IEEE International Symposium on Intelligent Signal Processing. https://doi.org/10.1109/wisp.2009.5286542
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.