The DOI matches its Crossref record.
Hosting Capacity Estimation of Underground Distribution Feeder in Urbain Areas
Abstract
Integrating new plants of renewable energies for electrical production in a distribution network presents challenges for the grid operators. However, the power systems are not designed to receive these intermittent renewable energy sources. The distributed generation (DG) integration causes several problems such as overvoltage, lines overload, transformers overload, protection issues, and exceeding network limits. The hosting capacity approach (HCA) defined the hosting capacity (HC) as the maximum power that will be injected into the gird without causing any problem in the electrical system. In this paper, we propose a new method to calculate the HC of distributed generation (DG) facilities. Therefore, the variety of distribution line configurations and cross admittance are considered in the calculation and the overvoltage as a limit of HC. The proposed method is applied to an underground medium voltage grid. The simulation is carried out using Matlab and Etap.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The HC differs with the load when overvoltage, line overload, and transformer overload are the limiting factors.
“The results obtained reveal that HC differs with the load when overvoltage, line overload, and transformer overload are the limiting factors.”
From Methods and Tools for PV and EV Hosting Capacity Determination in Low Voltage Distribution Networks—A Review (2023) · cites this paper as [61]
The deterministic method considers worst-case scenarios to determine HC due to the extreme impact of uncertain parameters.
“The deterministic method also considers the worst-case scenarios to determine the HC due to the extreme impact of uncertain parameters [60][61][62].”
From Methods and Tools for PV and EV Hosting Capacity Determination in Low Voltage Distribution Networks—A Review (2023) · cites this paper as [61]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 8
- 10.3390/en11020465 · DOI
- 10.1049/oap-cired.2017.0316 · DOI
- abad, 2017, Sensitivity of Hosting Capacity to Data Resolution and Uncertainty Modeling, Proceedings of the 2018 Australasian Universities Power Engineering Conference (AUPEC)
- 10.1109/PESGM.2016.7741861 · DOI
- 10.1109/ICPEICES.2016.7853653 · DOI
- 10.1109/TPWRS.2012.2237043 · DOI
- 10.3390/en11010255 · DOI
- ismael, 2018, State-of-the-art of hosting capacity in modern power systems with distributed generation, Renewable Energy
Cited by
Sorted by citations
A Review of the Tools and Methods for Distribution Networks’ Hosting Capacity Calculation
Zain ul Abideen, M., Ellabban, O., & Al-Fagih, L. (2020) · Energies · doi:10.3390/en13112758 · Cited by 161
Umoh, V., Davidson, I., Adebiyi, A., & Ekpe, U. (2023) · Energies · doi:10.3390/en16083609 · Cited by 71
Metadata
- Authors
- Soukaina, N., Hassane, E., Hassan, E. M., & Tijani, L.
- Affiliations
- Sidi Mohamed Ben Abdellah University (MA)
- Venue
- 2019 International Conference on Wireless Technologies, Embedded and Intelligent Systems (WITS)
- Publisher
- IEEE
- Published
- 2019-04
- Pages
- 1-5
- OpenAlex
- W2947677981
- Cited by
- 12
- References
- 0
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 5 · 2022: 2 · 2020: 3
- FWCI
- 1.99
- Type
- conference paper
- Language
- en
- Open access
- closed
- Licence
- Locations
- International Conference on Wireless Technologies, Embedded and Intelligent Systems (WITS) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Thermal Analysis in Power Transmission
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- hosting capacity, distributed generation, medium-voltage distribution networks, overvoltage, renewable energy integration, urban power distribution
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review