The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Direct comparison of binding equilibrium, thermodynamic, and rate constants determined by surface‐ and solution‐based biophysical methods
Open accessAbstract
The binding interactions of small molecules with carbonic anhydrase II were used as model systems to compare the reaction constants determined from surface‐ and solution‐based biophysical methods. Interaction data were collected for two arylsulfonamide compounds, 4‐carboxybenzenesulfonamide (CBS) and 5‐dimethyl‐amino‐1‐naphthalene‐sulfonamide (DNSA), binding to the enzyme using surface plasmon resonance, isothermal titration calorimetry, and stopped‐flow fluorescence. We demonstrate that when the surface plasmon resonance biosensor experiments are performed with care, the equilibrium, thermodynamic, and kinetic constants determined from this surface‐based technique match those acquired in solution. These results validate the use of biosensor technology to collect reliable data on small molecules binding to immobilized macromolecular targets. Binding kinetics were shown to provide more detailed information about complex formation than equilibrium constants alone. For example, although carbonic anhydrase II bound DNSA with twofold higher affinity than CBS, kinetic analysis revealed that CBS had a fourfold slower dissociation rate. Analysis of the binding and transition state thermodynamics also revealed significant differences in the enthalpy and entropy of complex formation. The lack of labeling requirements, high information content, and high throughput of surface plasmon resonance biosensors will make this technology an important tool for characterizing the interactions of small molecules with enzymes and receptors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Johnsson, B., Löfås, S., & Lindquist, G. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90424-r · Cited by 1,262
Kinetic analysis of macromolecular interactions using surface plasmon resonance biosensors
Myszka, D. G. (1997) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(97)80157-7 · Cited by 552
Self-citationMyszka, D. G., He, X., Dembo, M., Morton, T. A., & Goldstein, B. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77549-6 · Cited by 415
Self-citationMorton, T. A., Myszka, D. G., & Chaiken, I. M. (1995) · Analytical Biochemistry · doi:10.1006/abio.1995.1268 · Cited by 334
Self-citation[13] Kinetic analysis of macromolecular interactions using surface plasmon resonance biosensors
Morton, T. A., & Myszka, D. G. (1998) · Methods in Enzymology · doi:10.1016/s0076-6879(98)95044-3 · Cited by 308
Self-citationKinetic and Concentration Analysis Using BIA Technology
Karlsson, R., Roos, H., Fägerstam, L., & Persson, B. (1994) · Methods · doi:10.1006/meth.1994.1013 · Cited by 277
Kinetic, equilibrium, and thermodynamic analysis of macromolecular interactions with BIACORE
Myszka, D. G. (2000) · Methods in Enzymology · doi:10.1016/s0076-6879(00)23372-7 · Cited by 208
Self-citationSurvey of the 1999 surface plasmon resonance biosensor literature
Rich, R. L., & Myszka, D. G. (2000) · Journal of Molecular Recognition · doi:10.1002/1099-1352(200011/12)13:6<388::aid-jmr516>3.0.co;2-# · Cited by 127
Self-citationKarlsson, R., Kullman-Magnusson, M., Hämäläinen, M., Remaeus, A., Andersson, K., Borg, P., Gyzander, E., & Deinum, J. (2000) · Analytical Biochemistry · doi:10.1006/abio.1999.4406 · Cited by 126
Thermodynamic analysis of protein interactions with biosensor technology
Roos, H., Karlsson, R., Nilshans, H., & Persson, A. (1998) · Journal of Molecular Recognition · Cited by 110
Myszka, D. G. (1999) · Journal of Molecular Recognition · doi:10.1002/(sici)1099-1352(199909/10)12:5<279::aid-jmr473>3.0.co;2-3
Self-citation
Cited by
Krishnamurthy, V. M., Kaufman, G. K., Urbach, A. R., Gitlin, I., Gudiksen, K. L., Weibel, D. B., & Whitesides, G. M. (2008) · Chemical Reviews · doi:10.1021/cr050262p · Cited by 761
Label-free detection of small-molecule–protein interactions by using nanowire nanosensors
Wang, W. U., Chen, C., Lin, K.-H., Fang, Y., & Lieber, C. M. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406368102 · Cited by 534
Drug–protein binding: a critical review of analytical tools
Vuignier, K., Schappler, J., Veuthey, J.-L., Carrupt, P.-A., & Martel, S. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3737-1 · Cited by 389
Targeting Protein–Protein Interactions and Fragment-Based Drug Discovery
Valkov, E., Sharpe, T., Marsh, M., Greive, S., & Hyvönen, M. (2011) · Topics in Current Chemistry · doi:10.1007/128_2011_265 · Cited by 107
Metadata
- Authors
- Day, Y. S. N., Baird, C. L., Rich, R. L., & Myszka, D. G.
- Venue
- Protein Science
- Publisher
- Wiley
- Published
- 2002-05
- Volume
- 11
- Issue
- 5
- Pages
- 1017-1025
- ISSN
- 0961-8368 (ISSN-L)
- 1469-896X
- OpenAlex
- W2156294304
- Cited by
- 272
- References
- 11
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.