The Determination of Lipids and Proteins in Suction Blister Fluid
Open accessThe DOI matches its Crossref record.
Abstract
The concentration of 5 different proteins in suction blister fluid and serum was determined by immunotechniques. These proteins, varying in size and molecular weight (6,600-2,300,000) were insulin, albumin, high density lipoprotein determined as apoprotein A-I, alpha 2-macroglobulin and low density lipoprotein measured as apoprotein B. The difference in the blister fluid/serum concentration ratio of the proteins was dependent on the molecular weight and followed mainly the law of diffusion. Moreover, the amounts of insulin, albumin and apoproteins A-I and B in suction blister fluid were the same as those reported in peripheral lymph. The results indicate that the sieve function of the capillary basement membrane remains intact during the formation of the suction blisters. Suction blister fluid might therefore be regarded as representative of interstitial fluid. The concentrations of 4 different lipids (cholesterol, cholesterolesters, triglycerides and phospholipids) were also determined and their blister fluid/serum concentration ratio proved to have a fairly constant value of 0.25.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Wiig, H., & Swartz, M. A. (2012) · Physiological Reviews · doi:10.1152/physrev.00037.2011 · Cited by 722
Opportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
Interstitial fluid lipoproteins.
Sloop, C. H., Dory, L., & Roheim, P. S. (1987) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)38701-0 · Cited by 228
Biomolecular sensors for advanced physiological monitoring
Flynn, C. D., Chang, D., Mahmud, A., Yousefi, H., Das, J., Riordan, K. T., Sargent, E. H., & Kelley, S. O. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00067-z · Cited by 226
Metadata
- Authors
- Vermeer, B. J., Reman, F. C., & van Gent, C. M.
- Venue
- Journal of Investigative Dermatology
- Publisher
- Elsevier BV
- Published
- 1979-10
- Volume
- 73
- Issue
- 4
- Pages
- 303-305
- ISSN
- 0022-202X (ISSN-L)
- OpenAlex
- W2029481246
- Cited by
- 135
- References
- 0
- FWCI
- 1.96
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Determination of Lipids and Proteins in Suction Blister Fluid. https://app.cochat.ai/papers/10.1111/1523-1747.ep12531833
- The paper
- Vermeer, B. J., Reman, F. C., & van Gent, C. M. (1979). The Determination of Lipids and Proteins in Suction Blister Fluid. Journal of Investigative Dermatology. https://doi.org/10.1111/1523-1747.ep12531833
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.