CoChat

Accounting for Nonignorable Verification Bias in Assessment of Diagnostic Tests

Kosinski, Andrzej S., Barnhart, Huiman X. · 2003 · Biometrics
Cited by 79

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Summary. A “gold” standard test, providing definitive verification of disease status, may be quite invasive or expensive. Current technological advances provide less invasive, or less expensive, diagnostic tests. Ideally, a diagnostic test is evaluated by comparing it with a definitive gold standard test. However, the decision to perform the gold standard test to establish the presence or absence of disease is often influenced by the results of the diagnostic test, along with other measured, or not measured, risk factors. If only data from patients who received the gold standard test were used to assess the test performance, the commonly used measures of diagnostic test performance—sensitivity and specificity—are likely to be biased. Sensitivity would often be higher, and specificity would be lower, than the true values. This bias is called verification bias. Without adjustment for verification bias, one may possibly introduce into the medical practice a diagnostic test with apparent, but not truly, high sensitivity. In this article, verification bias is treated as a missing covariate problem. We propose a flexible modeling and computational framewzork for evaluating the performance of a diagnostic test, with adjustment for nonignorable verification bias. The presented computational method can be utilized with any software that can repetitively use a logistic regression module. The approach is likelihood‐based, and allows use of categorical or continuous covariates. An explicit formula for the observed information matrix is presented, so that one can easily compute standard errors of estimated parameters. The methodology is illustrated with a cardiology data example. We perform a sensitivity analysis of the dependency of verification selection process on disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/1541-0420.00019

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 79

Metadata

Authors
Kosinski, A. S., & Barnhart, H. X.
Venue
Biometrics
Published
2003-03
Volume
59
Issue
1
Pages
163-171
ISSN
  • 0006-341X (ISSN-L)
  • 1541-0420
OpenAlex
W2132965523
Cited by
79
References
2
FWCI
4.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accounting for Nonignorable Verification Bias in Assessment of Diagnostic Tests. https://app.cochat.ai/papers/10.1111/1541-0420.00019
The paper
Kosinski, A. S., & Barnhart, H. X. (2003). Accounting for Nonignorable Verification Bias in Assessment of Diagnostic Tests. Biometrics. https://doi.org/10.1111/1541-0420.00019

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.