Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 160

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Systematic Review: Emergency Department Bedside Ultrasonography for Diagnosing Suspected Abdominal Aortic Aneurysm

Open access
Rubano, Elizabeth, Mehta, Ninfa, Caputo, William, Paladino, Lorenzo, Sinert, Richard·2013·Academic Emergency Medicine

Abstract

Background: The use of ultrasound (US) to diagnose an abdominal aortic aneurysm (AAA) has been well studied in the radiology literature, but has yet to be rigorously reviewed in the emergency medicine arena. Objectives: This was a systematic review of the literature for the operating characteristics of emergency department (ED) ultrasonography for AAA. Methods: The authors searched PubMed and EMBASE databases for trials from 1965 through November 2011 using a search strategy derived from the following PICO formulation: Patients—patients (18+ years) suspected of AAA. Intervention—bedside ED US to detect AAA. Comparator—reference standard for diagnosing an AAA was a computed tomography (CT), magnetic resonance imaging (MRI), aortography, official US performed by radiology, ED US reviewed by radiology, exploratory laparotomy, or autopsy results. AAA was defined as ≥3 cm dilation of the aorta. Outcome—operating characteristics (sensitivity, specificity, and likelihood ratios [LR]) of ED abdominal US. The papers were analyzed using Quality Assessment of Diagnostic Accuracy Studies (QUADAS) guidelines. Results: The initial search strategy identified 1,238 articles; application of inclusion/exclusion criteria resulted in seven studies with 655 patients. The weighted average prevalence of AAA in symptomatic patients over the age of 50 years is 23%. On history, 50% of AAA patients will lack the classic triad of hypotension, back pain, and pulsatile abdominal mass. The sensitivity of abdominal palpation for AAA increases as the diameter of the AAA increases. The pooled operating characteristics of ED US for the detection of AAA were sensitivity 99% (95% confidence interval [CI] = 96% to 100%) and specificity 98% (95% CI = 97% to 99%). Conclusions: Seven high‐quality studies of the operating characteristics of ED bedside US in diagnosing AAA were identified. All showed excellent diagnostic performance for emergency bedside US to detect the presence of AAA in symptomatic patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/acem.12080

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 160

Metadata

Authors
Rubano, E., Mehta, N., Caputo, W., Paladino, L., & Sinert, R.
Venue
Academic Emergency Medicine
Publisher
Wiley
Published
2013-02
Volume
20
Issue
2
Pages
128-138
ISSN
  • 1069-6563 (ISSN-L)
  • 1553-2712
OpenAlex
W2074620590
Cited by
160
References
2
FWCI
1.73
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Systematic Review: Emergency Department Bedside Ultrasonography for Diagnosing Suspected Abdominal Aortic Aneurysm. https://app.cochat.ai/papers/10.1111/acem.12080
The paper
Rubano, E., Mehta, N., Caputo, W., Paladino, L., & Sinert, R. (2013). Systematic Review: Emergency Department Bedside Ultrasonography for Diagnosing Suspected Abdominal Aortic Aneurysm. Academic Emergency Medicine. https://doi.org/10.1111/acem.12080

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.