Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 186

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Microarray Diagnosis of Antibody-Mediated Rejection in Kidney Transplant Biopsies: An International Prospective Study (INTERCOM)

Open access
Halloran, P.F., Pereira, A.B., Chang, J., Matas, A., Picton, M., De Freitas, D., Bromberg, J., Serón, D., Sellarés, J., Einecke, G., Reeve, J. · 2013 · American Journal of Transplantation

Abstract

In a reference set of 403 kidney transplant biopsies, we recently developed a microarray-based test that diagnoses antibody-mediated rejection (ABMR) by assigning an ABMR score. To validate the ABMR score and assess its potential impact on practice, we performed the present prospective INTERCOM study (clinicaltrials.gov NCT01299168) in 300 new biopsies (264 patients) from six centers: Baltimore, Barcelona, Edmonton, Hannover, Manchester and Minneapolis. We assigned ABMR scores using the classifier created in the reference set and compared it to conventional assessment as documented in the pathology reports. INTERCOM documented uncertainty in conventional assessment: In 41% of biopsies where ABMR features were noted, the recorded diagnoses did not mention ABMR. The ABMR score correlated with ABMR histologic lesions and donor-specific antibodies, but not with T cell-mediated rejection lesions. The agreement between ABMR scores and conventional assessment was identical to that in the reference set (accuracy 85%). The ABMR score was more strongly associated with failure than conventional assessment, and when the ABMR score and conventional assessment disagreed, only the ABMR score was associated with early progression to failure. INTERCOM confirms the need to reduce uncertainty in the diagnosis of ABMR, and demonstrates the potential of the ABMR score to impact practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/ajt.12465

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 186

Metadata

Authors
Halloran, P. F., Pereira, A. B., Chang, J., Matas, A., Picton, M., De Freitas, D., Bromberg, J., Serón, D., Sellarés, J., Einecke, G., & Reeve, J.
Venue
American Journal of Transplantation
Publisher
Elsevier BV
Published
2013-11
Volume
13
Issue
11
Pages
2865-2874
ISSN
1600-6135 (ISSN-L)
OpenAlex
W1854548644
Cited by
186
References
2
FWCI
11.42
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microarray Diagnosis of Antibody-Mediated Rejection in Kidney Transplant Biopsies: An International Prospective Study (INTERCOM). https://app.cochat.ai/papers/10.1111/ajt.12465
The paper
Halloran, P. F., Pereira, A. B., Chang, J., Matas, A., Picton, M., De Freitas, D., Bromberg, J., Serón, D., Sellarés, J., Einecke, G., & Reeve, J. (2013). Microarray Diagnosis of Antibody-Mediated Rejection in Kidney Transplant Biopsies: An International Prospective Study (INTERCOM). American Journal of Transplantation. https://doi.org/10.1111/ajt.12465

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.