Minimum alveolar concentration: ongoing relevance and clinical utility
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Summary: Since its introduction in 1965, minimum alveolar concentration ( MAC ) has served as the standard measure of potency for volatile anaesthetic agents. It is defined as the minimum alveolar concentration of inhaled anaesthetic at which 50% of people do not move in response to a noxious stimulus. Within the last 20 years, it has been discovered that volatile anaesthetics inhibit mobility largely through action on the spinal cord, whereas the amnesic and hypnotic effects are mediated by the brain. Studies suggest that the concentration of volatile anaesthetic needed to prevent explicit memory from developing, and to produce unconsciousness, is usually substantially lower than the concentration required to prevent movement in response to surgery. This review highlights the contributions and limitations of MAC and its derivatives as metrics of anaesthetic potency with respect to particular behavioural outcomes. Recent evidence is presented suggesting that a protocol that alerts anaesthetists whenever MAC falls to < 0.5 or 0.7 has the potential to decrease intra‐operative awareness with explicit recall, possibly to a similar extent as does a protocol based on processed electroencephalography‐driven alerting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Do general anaesthetics act by competitive binding to specific receptors?
Franks, N. P., & Lieb, W. R. (1984) · Nature · doi:10.1038/310599a0 · Cited by 572 · cited 1×
“Although volatile anaesthetics bind to protein targets [8], the Meyer-Overton relationship, that volatile anaesthetic potency varies directly with lipid solubility [9, 10], holds true for commonly used inhaled anaes-”
BackgroundUnresponsiveness ≠ unconsciousness
Sanders, R. D., Tononi, G., Laureys, S., Sleigh, J. W., & Warner, D. S. (2012) · Anesthesiology · doi:10.1097/aln.0b013e318249d0a7 · Cited by 474
Friedman, E. B., Sun, Y., Moore, J. T., Hung, H.-T., Meng, Q. C., Perera, P., Joiner, W. J., Thomas, S. A., Eckenhoff, R. G., Sehgal, A., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0011903 · Cited by 218
Sonner, J. M., Gong, D., Li, J., Eger, E. I., & Laster, M. J. (1999) · Anesthesia & Analgesia · doi:10.1213/00000539-199910000-00039 · Cited by 100
Metadata
- Authors
- Aranake, A., Mashour, G. A., & Avidan, M. S.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2013-02-16
- Volume
- 68
- Issue
- 5
- Pages
- 512-522
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W2154228706
- Cited by
- 186
- References
- 4
- FWCI
- 10.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Minimum alveolar concentration: ongoing relevance and clinical utility. https://app.cochat.ai/papers/10.1111/anae.12168
- The paper
- Aranake, A., Mashour, G. A., & Avidan, M. S. (2013). Minimum alveolar concentration: ongoing relevance and clinical utility. Anaesthesia. https://doi.org/10.1111/anae.12168
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.