Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 198

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Videolaryngoscopy vs. fibreoptic bronchoscopy for awake tracheal intubation: a systematic review and meta‐analysis

Alhomary, M., Ramadan, E., Curran, E., Walsh, S. R. · 2018 · Anaesthesia

Abstract

Summary: Awake fibreoptic intubation is often considered the technique of choice when a difficult airway is anticipated. However, videolaryngoscopes are being used more commonly. We searched the current literature and performed a meta‐analysis to compare the use of videolaryngoscopy and fibreoptic bronchoscopy for awake tracheal intubation. Our primary outcome was the time needed to intubate the patient's trachea. Secondary outcomes included: failed intubation; the rate of successful intubation at the first attempt; patient‐reported satisfaction with the technique; and any complications resulting from intubation. Eight studies examining 429 patients were included in this review. The intubation time was shorter when videolaryngoscopy was used instead of fibreoptic bronchoscopy (seven trials, 408 participants, mean difference (95%CI) −45.7 (−66.0 to −25.4) s, p < 0.0001, low‐quality evidence). There was no significant difference between the two techniques in the failure rate (six studies, 355 participants, risk ratio (95%CI) 1.01 (0.24–4.35), p = 0.99, low‐quality evidence) or the first‐attempt success rate (six studies, 391 participants, risk ratio (95%CI) 1.01 (0.95–1.06), p = 0.8, moderate quality evidence). The level of patient satisfaction was similar between both groups. No difference was found in two reported adverse events: hoarseness/sore throat (three studies, 167 participants, risk ratio (95%CI) 1.07 (0.62–1.85), p = 0.81, low‐quality evidence), and low oxygen saturation (five studies, 337 participants, risk ratio (95%CI) 0.49 (0.22–1.12), p = 0.09, low‐quality evidence). In summary, videolaryngoscopy for awake tracheal intubation is associated with a shorter intubation time. It also seems to have a success rate and safety profile comparable to fibreoptic bronchoscopy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/anae.14299

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 198

Metadata

Authors
Alhomary, M., Ramadan, E., Curran, E., & Walsh, S. R.
Venue
Anaesthesia
Publisher
Wiley
Published
2018-04-17
Volume
73
Issue
9
Pages
1151-1161
ISSN
  • 0003-2409 (ISSN-L)
  • 1365-2044
OpenAlex
W2801741994
Cited by
198
References
4
FWCI
4.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.