Cited by 11ECG Monitoring and AnalysisCardiac electrophysiology and arrhythmiasHealthcare Technology and Patient Monitoring

Ambulatory electrocardiographic monitoring between artifacts and misinterpretation, management errors of commission and errors of omission

Open access
El‐Sherif, Nabil, Turitto, Gioia·2015·Annals of Noninvasive Electrocardiology

Abstract

Background: The aim of the study is to contrast the role of conventional ambulatory electrocardiographic monitoring (AEM) artifacts with a less emphasized problem with potentially more serious implications, that is, the failure to recognize, and therefore misinterpret, a genuine arrhythmia episode in the AEM recording. Methods: The study material included 500 Holter recordings and 500 recordings from the cardiac telemetry unit. Results: Electrocardiographic (ECG) artifacts were more common in telemetry recordings (5.6%) compared to Holter recordings (4%) for a total of 4.8%. There were 35 examples of misinterpretation of AEM recordings (3.5%). These were significantly more common in telemetry recordings (2.6%) compared to Holter recordings (0.9%). The most common ECG artifacts were examples of pseudo ventricular tachyarrhythmia (VT). The majority of misinterpretation (26 of 35 examples) were fast supraventricular tachyarrhythmias with aberrant QRS (including six examples of atrial flutter with periods of 1:1 atrioventricular conduction) that were misdiagnosed as ventricular VT. Other examples were misinterpretation of arrhythmic episodes consistent with sick sinus syndrome, pacemaker malfunction, and long QT syndrome. Only 5 of 48 examples of AEM artifacts resulted in management errors of commission or errors of omission compared to all 35 examples of misinterpretation. Conclusions: Compared to conventional artifacts in AEM, misinterpretation of nonartifactual arrhythmic episodes consistently resulted in management errors. Misinterpretation was significantly more common with telemetry recordings compared to Holter ECG. This highlights the need for more appropriate training of the entire clinical team in charge of the management of the cardiac telemetry unit.

Integrity signals

Registry

Crossref · 10.1111/anec.12222

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Failure by the technician or clinician to recognize a genuine arrhythmia episode in the ECG recording may lead to potentially more serious implications.

    “In contrast to the role of the more common AECG artifacts, failure by the technician or clinician to recognize a genuine arrhythmia episode in the ECG recording may lead to potentially more serious implications (El-Sherif & Turitto, 2015).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
El‐Sherif, N., & Turitto, G.
Affiliations
  • SUNY Downstate Health Sciences University (US)
  • NewYork–Presbyterian Brooklyn Methodist Hospital (US)
Venue
Annals of Noninvasive Electrocardiology
Publisher
Wiley
Published
2014-11-04
Volume
20
Issue
3
Pages
282-289
ISSN
  • 1082-720X (ISSN-L)
  • 1542-474X
OpenAlex
W2133317645
Cited by
11
References
3
Citations by year
2026: 1 · 2024: 1 · 2023: 2 · 2021: 1 · 2019: 1 · 2017: 2 · 2016: 1 · 2015: 2
FWCI
1.15
Type
journal article
Language
en
Open access
Locations
  • Annals of Noninvasive Electrocardiology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
Keywords
Holter monitoring, ECG artifacts, cardiac telemetry, supraventricular tachycardia, atrial flutter, sick sinus syndrome, pacemaker malfunction, long QT syndrome, commission errors, omission errors
MeSH terms
Adult, Aged, Arrhythmias, Cardiac, Diagnostic Errors, Female, Humans, Male, Middle Aged, Electrocardiography, Ambulatory, Artifacts, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review