CoChat

Systematic review of reusable versus disposable laparoscopic instruments: costs and safety

Open access
Siu, Joey, Hill, Andrew G., MacCormick, Andrew D. · 2017 · ANZ Journal of Surgery
Cited by 104

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: The quality of instruments and surgical expertise in minimally invasive surgery has developed markedly in the last two decades. Attention is now being turned to ways to allow surgeons to adopt more cost‐effective and environmental‐friendly approaches. This review explores current evidence on the cost and environmental impact of reusable versus single‐use instruments. In addition, we aim to compare their quality, functionality and associated clinical outcomes. Method: The Medline and EMBASE databases were searched for relevant literature from January 2000 to May 2015. Subject headings were Equipment Reuse/, Disposable Equipment/, Cholecystectomy/, Laparoscopic/, Laparoscopy/, Surgical Instruments/, Medical Waste Disposal/, Waste Management/, Medical Waste/, Environmental Sustainability/ and Sterilization/. Results: There are few objective comparative analyses between single‐use versus reusable instruments. Current evidence suggests that limiting use of disposal instruments to necessity may hold both economical and environmental advantages. Theoretical advantages of single‐use instruments in quality, safety, sterility, ease of use and importantly patient outcomes have rarely been examined. Cost‐saving methods, environmental‐friendly methods, global operative costs, hidden costs, sterilization methods and quality assurance systems vary greatly between studies making it difficult to gain an overview of the comparison between single‐use and reusable instruments. Conclusions: Further examination of cost comparisons between disposable and reusable instruments is necessary while externalized environmental costs, instrument function and safety are also important to consider in future studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/ans.13856

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Eco-efficiency of disposable and reusable surgical instruments - a scissors case

    Ibbotson, S., Dettmer, T., Kara, S., & Herrmann, C. (2013) · The International Journal of Life Cycle Assessment · doi:10.1007/s11367-013-0547-7 · Cited by 115 · cited 6×

    “A comparative life cycle assessment is an analytic tool that can be used to evaluate the resource usage and environmental effects of all stages of a product or activity to aid environmental decision-making.(3) A cradle-tograve type life cycle assessment in healthcare ranges from the extraction of raw materials used fo…”
    BackgroundMethodInfluential

Show all 1 references

Cited by

See all 104

Metadata

Authors
Siu, J., Hill, A. G., & MacCormick, A. D.
Venue
ANZ Journal of Surgery
Publisher
Wiley
Published
2016-11-23
Volume
87
Issue
1-2
Pages
28-33
ISSN
  • 1445-1433 (ISSN-L)
  • 1445-2197
OpenAlex
W2559318419
Cited by
104
References
1
FWCI
0.77
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Systematic review of reusable versus disposable laparoscopic instruments: costs and safety. https://app.cochat.ai/papers/10.1111/ans.13856
The paper
Siu, J., Hill, A. G., & MacCormick, A. D. (2017). Systematic review of reusable versus disposable laparoscopic instruments: costs and safety. ANZ Journal of Surgery. https://doi.org/10.1111/ans.13856

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.