Impact of controlled attenuation parameter on detecting fibrosis using liver stiffness measurement
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Summary: Background: Liver fibrosis is often accompanied by steatosis, particularly in patients with non‐alcoholic fatty liver disease (NAFLD), and its non‐invasive characterisation is of utmost importance. Vibration‐controlled transient elastography is the non‐invasive method of choice; however, recent research suggests that steatosis may influence its diagnostic performance. Controlled Attenuation Parameter (CAP) added to transient elastography enables simultaneous assessment of steatosis and fibrosis. Aim: To determine how to use CAP in interpreting liver stiffness measurements. Methods: This is a secondary analysis of data from an individual patient data meta‐analysis on CAP. The main exclusion criteria for the current analysis were unknown aetiology, unreliable elastography measurement and data already used for the same research question. Aetiology‐specific liver stiffness measurement cut‐offs were determined and used to estimate positive and negative predictive values (PPV/NPV) with logistic regression as functions of CAP. Results: Two thousand and fifty eight patients fulfilled the inclusion criteria (37% women, 18% NAFLD/NASH, 42% HBV, 40% HCV, 51% significant fibrosis ≥ F2). Youden optimised cut‐offs were only sufficient for ruling out cirrhosis (NPV of 98%). With sensitivity and specificity‐optimised cut‐offs, NPV for ruling out significant fibrosis was moderate (70%) and could be improved slightly through consideration of CAP. PPV for significant fibrosis and cirrhosis were 68% and 55% respectively, despite specificity‐optimised cut‐offs for cirrhosis. Conclusions: Liver stiffness measurement values below aetiology‐specific cut‐offs are very useful for ruling out cirrhosis, and to a lesser extent for ruling out significant fibrosis. In the case of the latter, Controlled Attenuation Parameter can improve interpretation slightly. Even if cut‐offs are very high, liver stiffness measurements are not very reliable for ruling in fibrosis or cirrhosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
EASL–EASD–EASO Clinical Practice Guidelines for the management of non-alcoholic fatty liver disease
(2016) · Journal of Hepatology · doi:10.1016/j.jhep.2015.11.004 · Cited by 4,836
(2015) · Journal of Hepatology · doi:10.1016/j.jhep.2015.04.006 · Cited by 1,875
Karlas, T., Petroff, D., Sasso, M., Fan, J.-G., Mi, Y.-Q., de Lédinghen, V., Kumar, M., Lupsor-Platon, M., Han, K.-H., Cardoso, A. C., et al. (2017) · Journal of Hepatology · doi:10.1016/j.jhep.2016.12.022 · Cited by 1,275 · cited 4×
“An inherent fact when collecting individual patient data worldwide is that histological evaluation and biopsy quality may differ between sites as was pointed out in the primary paper, which may be even more relevant in fibrosis staging and requires conversion between scoring systems.(16) This and further limitations c…”
BackgroundMethodInfluentialSelf-citation
Cited by
Berzigotti, A., Tsochatzis, E., Boursier, J., Castera, L., Cazzagon, N., Friedrich-Rust, M., Petta, S., & Thiele, M. (2021) · Journal of Hepatology · doi:10.1016/j.jhep.2021.05.025 · Cited by 1,925
Self-citationHsu, C., Caussy, C., Imajo, K., Chen, J., Singh, S., Kaulback, K., Le, M.-D., Hooker, J., Tu, X., Bettencourt, R., et al. (2019) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2018.05.059 · Cited by 415
Pons, M., Augustin, S., Scheiner, B., Guillaume, M., Rosselli, M., Rodrigues, S. G., Stefanescu, H., Ma, M. M., Mandorfer, M., Mergeay-Fabre, M., et al. (2021) · American Journal of Gastroenterology · doi:10.14309/ajg.0000000000000994 · Cited by 260
Wong, V. W.-S., Irles, M., Wong, G. L.-H., Shili, S., Chan, A. W.-H., Merrouche, W., Shu, S. S.-T., Foucher, J., Le Bail, B., Chan, W. K., et al. (2019) · Gut · doi:10.1136/gutjnl-2018-317334 · Cited by 174
Self-citationAuthors, & Collaborators: (2022) · Zeitschrift für Gastroenterologie · doi:10.1055/a-1880-2388 · Cited by 30
Metadata
- Authors
- Karlas, T., Petroff, D., Sasso, M., Fan, J. ‐., Mi, Y. ‐., de Lédinghen, V., Kumar, M., Lupsor‐Platon, M., Han, K. ‐., Cardoso, A. C., Ferraioli, G., Chan, W. ‐., Wong, V. W. ‐., Myers, R. P., Chayama, K., Friedrich‐Rust, M., Beaugrand, M., Shen, F., Hiriart, J. ‐., Sarin, S. K., Badea, R., Lee, H. W., Marcellin, P., Filice, C., Mahadeva, S., Wong, G. L. ‐., Crotty, P., Masaki, K., Bojunga, J., Bedossa, P., Keim, V., & Wiegand, J.
- Venue
- Alimentary Pharmacology & Therapeutics
- Publisher
- Wiley
- Published
- 2018-02-15
- Volume
- 47
- Issue
- 7
- Pages
- 989-1000
- ISSN
- 0269-2813 (ISSN-L)
- 1365-2036
- OpenAlex
- W2789266617
- Cited by
- 52
- References
- 3
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of controlled attenuation parameter on detecting fibrosis using liver stiffness measurement. https://app.cochat.ai/papers/10.1111/apt.14529
- The paper
- Karlas, T., Petroff, D., Sasso, M., Fan, J. ‐., Mi, Y. ‐., de Lédinghen, V., Kumar, M., Lupsor‐Platon, M., Han, K. ‐., Cardoso, A. C., Ferraioli, G., Chan, W. ‐., Wong, V. W. ‐., Myers, R. P., Chayama, K., Friedrich‐Rust, M., Beaugrand, M., Shen, F., Hiriart, J. ‐., . . . Wiegand, J. (2018). Impact of controlled attenuation parameter on detecting fibrosis using liver stiffness measurement. Alimentary Pharmacology & Therapeutics. https://doi.org/10.1111/apt.14529
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.