CoChat

Association between ultrasound quality and test performance for HCC surveillance in patients with cirrhosis: a retrospective cohort study

Chong, Nicolas, Schoenberger, Haley, Yekkaluri, Sruthi, Fetzer, David T., Rich, Nicole E., Yokoo, Takeshi, Gopal, Purva, Manwaring, Carrie, Quirk, Lisa, Singal, Amit G. · 2022 · Alimentary Pharmacology & Therapeutics
Cited by 104

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Summary: Background: Ultrasound visualisation is limited in approximately 20% of patients with cirrhosis undergoing hepatocellular carcinoma (HCC) surveillance; however, it is unknown if impaired visualisation directly impacts test performance. We aimed to evaluate the association between ultrasound visualisation and surveillance test performance. Methods: We performed a retrospective cohort study among patients with cirrhosis, with or without HCC, who underwent ultrasound‐based surveillance at two large health systems between July 2016 and July 2019. Ultrasound visualisation assessment was recorded by interpreting radiologists using the ultrasound LI‐RADS Visualisation score. We performed logistic regression analyses to evaluate the association between ultrasound visualisation and diagnostic test performance. We assessed sensitivity for HCC detection among ultrasounds performed in the year prior to HCC diagnoses and specificity using ultrasounds in those without HCC. Results: Among 186 patients with HCC, severely limited visualisation (Vis Score C) on ultrasound prior to HCC diagnosis was associated with increased odds of false‐negative results, that is lower sensitivity (OR 7.94, 95% CI 1.23‐51.16) in multivariable analysis. Ultrasound sensitivity with visualisation scores A or B exceeded 75%, compared to only 27.3% with visualisation score C. Among 2052 cirrhosis patients without HCC, moderate visualisation limitations (Vis score B) were associated with increased odds of false‐positive results (OR 1.60, 1.13‐2.27), although specificity exceeded 95% across all visualisation scores. Conclusions: Impaired ultrasound visualisation is associated with worse surveillance test performance. Alternative blood‐based biomarkers and imaging strategies are needed for patients at risk for ultrasound‐based surveillance failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/apt.16779

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 104

Metadata

Authors
Chong, N., Schoenberger, H., Yekkaluri, S., Fetzer, D. T., Rich, N. E., Yokoo, T., Gopal, P., Manwaring, C., Quirk, L., & Singal, A. G.
Venue
Alimentary Pharmacology & Therapeutics
Publisher
Wiley
Published
2022-02-15
Volume
55
Issue
6
Pages
683-690
ISSN
  • 0269-2813 (ISSN-L)
  • 1365-2036
OpenAlex
W4212767717
Cited by
104
References
3
FWCI
11.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Association between ultrasound quality and test performance for HCC surveillance in patients with cirrhosis: a retrospective cohort study. https://app.cochat.ai/papers/10.1111/apt.16779
The paper
Chong, N., Schoenberger, H., Yekkaluri, S., Fetzer, D. T., Rich, N. E., Yokoo, T., Gopal, P., Manwaring, C., Quirk, L., & Singal, A. G. (2022). Association between ultrasound quality and test performance for HCC surveillance in patients with cirrhosis: a retrospective cohort study. Alimentary Pharmacology & Therapeutics. https://doi.org/10.1111/apt.16779

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.