CoChat

The usefulness of plasma histamine and different tryptase cut‐off points in the diagnosis of peranaesthetic hypersensitivity reactions

Berroa, F., Lafuente, A., Javaloyes, G., Ferrer, M., Moncada, R., Goikoetxea, M. J., Urbain, C. M., Sanz, M. L., Gastaminza, G. · 2014 · Clinical & Experimental Allergy
Cited by 44

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Summary: Anaesthetic hypersensitivity reactions can be I g E‐ or not I g E‐mediated and are a challenge to find the causal agent. Histamine and tryptase determination are classically considered useful in the diagnosis of these reactions. The aim of our study was to assess the diagnostic usefulness of plasma histamine and different cut‐off points of serum tryptase. Methods: Patients suffering a reaction suggestive of hypersensitivity during general anaesthesia in C línica U niversidad de N avarra (2008–2012) were included. Serum tryptase and plasma histamine were measured at the time of the reaction and 2 h later. Baseline tryptase was also determined. Four to eight weeks after the reaction an allergological study was performed to all the drugs or products involved in the reaction. Results: Sixty‐five patients suffered an immediate hypersensitivity reaction during the period of the study. Thirty‐seven patients (20 male) with median age 48 years (12–79) were included because they completed allergological study, and histamine and tryptase were correctly obtained. Elevated plasma histamine was observed in 34 cases (92%). Tryptase exceeded twice the basal values in 10 patients (31%). Using different cut‐off points of tryptase, the number of patients with elevated tryptase would be 15 patients (41%) for a cut‐off point of 5 μg/L; 12 patients (32%) for a cut‐off point of 8.23 μg/L; nine patients (24%) for 10.5 μg/L; and eight patients (22%) for 11.4 μg/L. The median tryptase level for the I g E‐mediated reactions was 9.0 μg/L (2–70 μg/L) and 4.0 μg/L (3–13 μg/L) in non‐I g E‐mediated reactions (P < 0.01). Median tryptase levels were higher in more severe reactions (grade 2 or 3) in comparison with grade 1. The best ratio for serum‐tryptase‐during‐reaction/basal‐serum‐tryptase to discriminate between I g E and non‐I g E reactions was 2.0. Conclusion: The best criterion for discriminating I g E‐ and non I g E‐mediated hypersensitivity reactions in anaesthesia was a tryptase value exceeding twice the basal one.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/cea.12237

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Berroa, F., Lafuente, A., Javaloyes, G., Ferrer, M., Moncada, R., Goikoetxea, M. J., Urbain, C. M., Sanz, M. L., & Gastaminza, G.
Venue
Clinical & Experimental Allergy
Publisher
Wiley
Published
2014-01-22
Volume
44
Issue
2
Pages
270-277
ISSN
  • 0954-7894 (ISSN-L)
  • 1365-2222
OpenAlex
W2161729132
Cited by
44
References
5
FWCI
3.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.