CoChat

Circadian hormone profiles and insulin sensitivity in patients with Addison's disease: a comparison of continuous subcutaneous hydrocortisone infusion with conventional glucocorticoid replacement therapy

Björnsdottir, Sigridur, Øksnes, Marianne, Isaksson, Magnus, Methlie, Paal, Nilsen, Roy M., Hustad, Steinar, Kämpe, Olle, Hulting, Anna‐Lena, Husebye, Eystein S., Løvås, Kristian, Nyström, Thomas, Bensing, Sophie · 2015 · Clinical Endocrinology
Cited by 43

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

Summary: Context: Conventional glucocorticoid replacement therapy in patients with Addison's disease (AD) is unphysiological with possible adverse effects on mortality, morbidity and quality of life. The diurnal cortisol profile can likely be restored by continuous subcutaneous hydrocortisone infusion (CSHI). Objective: The aim of this study was to compare circadian hormone rhythms and insulin sensitivity in conventional thrice‐daily regimen of glucocorticoid replacement therapy with CSHI treatment in patients with AD. Design and setting: An open, randomized, two‐period, 12‐week crossover multicentre trial in Norway and Sweden. Patients: Ten Norwegian patients were admitted for 24‐h sampling of hormone profiles. Fifteen Swedish patients underwent euglycaemic‐hyperinsulinaemic clamp. Intervention: Thrice‐daily regimen of oral hydrocortisone (OHC) and CSHI treatment. Main outcome measure: We measured the circadian rhythm of cortisol, adrenocorticotropic hormone (ACTH), growth hormone (GH), insulin‐like growth factor‐1, (IGF‐1), IGF‐binding protein‐3 (IGFBP‐3), glucose, insulin and triglycerides during OHC and CSHI treatment. Euglycaemic‐hyperinsulinaemic clamp was used to assess insulin sensitivity. Results: Continuous subcutaneous hydrocortisone infusion provided a more physiological circadian cortisol curve including a late‐night cortisol surge. ACTH levels showed a near normal circadian variation for CSHI. CSHI prevented a continuous decrease in glucose during the night. No difference in insulin sensitivity was observed between the two treatment arms. Conclusion: Continuous subcutaneous hydrocortisone infusion replacement re‐established a circadian cortisol rhythm and normalized the ACTH levels. Patients with CSHI replacement had a more stable night‐time glucose level compared with OHC without compromising insulin sensitivity. Thus, restoring night‐time cortisol levels might be advantageous for patients with AD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/cen.12670

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

Metadata

Authors
Björnsdottir, S., Øksnes, M., Isaksson, M., Methlie, P., Nilsen, R. M., Hustad, S., Kämpe, O., Hulting, A., Husebye, E. S., Løvås, K., Nyström, T., & Bensing, S.
Venue
Clinical Endocrinology
Publisher
Wiley
Published
2015-01-12
Volume
83
Issue
1
Pages
28-35
ISSN
  • 0300-0664 (ISSN-L)
  • 1365-2265
OpenAlex
W2018163800
Cited by
43
References
21
FWCI
3.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.