Cited by 20Neuroscience and Neural EngineeringRetinal Development and DisordersRetinal and Macular Surgery

Retinal prostheses: where to from here?

Allen, Penelope J.·2021·Clinical & Experimental Ophthalmology

Abstract

Researchers have been working towards the development of retinal prostheses, so called "bionic eyes" since the 1960s in an effort to restore functional vision to severely visually impaired patients. Groups from all around the world are involved in this research but in particular, groups from the United States, Germany, France, Japan and Australia have conducted clinical trials of these devices and three of these devices have achieved either FDA HDE (U.S. Food and Drug Administration Humanitarian Device Exception) or CE mark approval for commercial production. Despite this, all three of these devices are now not in commercial production. There are many challenges to overcome to develop devices suitable to implant in human patients and then reach commercial distribution. This is an exacting process and many hurdles need to be overcome to reach this point so that leaving the market after achieving this goal is a significant decision. Ongoing research is exploring the possibility of less complicated surgery with better visual processing algorithms to provide more useful visual information for our patients to provide a commercial alternative.

Integrity signals

Registry

Crossref · 10.1111/ceo.13950

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The number of people affected by RP is estimated to be about 1.5-2 million, but only 12% of these have a visual acuity worse than counting fingers and 0.5% have no perception of light.

    “The number of people affected by RP is estimated to be about 1.5-2 million [226], but only 12% of these have a visual acuity worse than counting fingers and 0.5% have no perception of light [227].”

The citation lists haven’t been fetched yet

References 44 · Cited by 20

Authors
Allen, P. J.
Affiliations
The University of Melbourne (AU)
Corresponding author
Allen, Penelope J.
Venue
Clinical & Experimental Ophthalmology
Publisher
Wiley
Published
2021-06-17
Volume
49
Issue
5
Pages
418-429
ISSN
  • 1442-6404 (ISSN-L)
  • 1442-9071
OpenAlex
W3162522428
Cited by
20
References
44
Citations by year
2026: 4 · 2025: 7 · 2024: 3 · 2023: 2 · 2022: 4
FWCI
1.04
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical and Experimental Ophthalmology (publishedVersion)
  • PubMed (publishedVersion)
  • Minerva Access (University of Melbourne) (submittedVersion)
Funders
  • Department of Health, State Government of Victoria
  • National Health and Medical Research Council (1082358)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Retinal Development and Disorders
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal and Macular Surgery
Keywords
retinal prosthesis, visual impairment, vision restoration, clinical trials, commercialization, surgical complexity
MeSH terms
Australia, Humans, Japan, United States, Vision, Ocular, Visual Perception, Visual Prosthesis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review