CoChat

Atrial Tachyarrhythmias and the Cox-maze Procedure in Congenital Heart Disease

Gutierrez, Sherrill D., Earing, Michael G., Singh, Anoop K., Tweddell, James S., Bartz, Peter J. · 2013 · Congenital Heart Disease
Cited by 30

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

INTRODUCTION: Atrial tachyarrhythmias, particularly atrial flutter and fibrillation, are commonly associated with congenital heart disease and are a major cause of morbidity and mortality. The Cox-maze procedure, introduced by Dr. James Cox in 1987, is effective at controlling atrial fibrillation in structurally normal hearts. Though the Cox-maze procedure has been used for atrial tachyarrhythmias in patients with congenital heart disease, few studies have looked at its effectiveness. METHODS: A retrospective chart review was performed on 24 patients with congenital heart disease who underwent the Cox-maze procedure at the Medical College of Wisconsin from 2004 through 2010. RESULTS: Mean age at time of Cox-maze procedure for the cohort was 40.9 years (range, 14 to 66 years). The most common congenital heart diseases among the patients included tetralogy of Fallot (n = 8) and atrioventricular septal defect (n = 4). All patients had concomitant cardiac procedures with the most common being right ventricular outflow tract reconstruction (n = 10), tricuspid valve repair (n = 8), and atrial septal defect repair (n = 7). Prior to the Cox-maze procedure, arrhythmias consisted of atrial flutter or intratrial reentrant tachycardia (n = 19) and atrial fibrillation (n = 5). There were three early postoperative deaths and one late postoperative death. Follow-up was available for 19 of 21 (90%) survivors with a mean length to follow-up from Cox-maze procedure of 2.8 years (range, 0.14-5.7 years). At last follow-up, 14 (74%) of the survivors remained arrhythmia-free. CONCLUSIONS: In patients with congenital heart disease and atrial tachyarrhythmias, the majority were rendered arrhythmia-free by the Cox-maze procedure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/chd.12031

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 30

Metadata

Authors
Gutierrez, S. D., Earing, M. G., Singh, A. K., Tweddell, J. S., & Bartz, P. J.
Venue
Congenital Heart Disease
Published
2012-12-27
Volume
8
Issue
5
Pages
n/a-n/a
ISSN
1747-079X (ISSN-L)
OpenAlex
W2155427201
Cited by
30
References
2
FWCI
1.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Atrial Tachyarrhythmias and the Cox-maze Procedure in Congenital Heart Disease. https://app.cochat.ai/papers/10.1111/chd.12031
The paper
Gutierrez, S. D., Earing, M. G., Singh, A. K., Tweddell, J. S., & Bartz, P. J. (2013). Atrial Tachyarrhythmias and the Cox-maze Procedure in Congenital Heart Disease. Congenital Heart Disease. https://doi.org/10.1111/chd.12031

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.