Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 225

The DOI matches its Crossref record.

Influence of Vertical Soft Tissue Thickness on Crestal Bone Changes Around Implants with Platform Switching: A Comparative Clinical Study

Linkevicius, Tomas, Puisys, Algirdas, Steigmann, Marius, Vindasiute, Egle, Linkeviciene, Laura · 2015 · Clinical Implant Dentistry and Related Research

Abstract

Background: Numerous studies have shown the superiority of platform‐switched implants in preserving crestal bone as compared with platform‐matched implants. However, the influence of initial soft tissue thickness on development of crestal bone loss has not been addressed in previous studies; thus, further research is needed. Purpose: To evaluate crestal bone levels around platform‐switched implants placed in thin and thick mucosal tissue. Materials and Methods: Eighty patients (38 male and 42 female, mean age 44 ± 3.34 years) received 80 bone‐level implants of 4.1 mm in diameter with platform switching (I nstitut S traumann AG, Basel, S witzerland). Tissue thickness was measured, and cases were distributed to Group 1, with thin soft tissue (2 mm or less, n = 40), and Group 2, with thick tissue (more than 2 mm, n = 40). Implants were placed with a one‐stage approach and restored with screw‐retained restorations. Radiographic examination was performed after implant placement, 2 months after healing, after restoration, and at 1‐year follow‐up post‐reconstruction. Crestal bone loss was calculated. The M ann‐W hitney U‐test was applied, and significance was set to p ≤ .05. Results: Implants in Group 1 (thin tissue) showed 0.79 mm of bone loss after 2 months. After 1‐year follow‐up, bone loss was 1.17 mm. Implants in Group 2 (thick tissue) showed bone loss of 0.17 mm after 2 months of implant placement and 0.21 mm after 1‐year follow‐up. The differences between groups were significant (p < .001) at both time points. Conclusions: It can be concluded that platform switching does not prevent crestal bone loss if, at the time of implant placement, mucosal tissue is thin. In thick soft tissue, use of platform‐switched implants maintained crestal bone level with minimal remodeling.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/cid.12222

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 225

Metadata

Authors
Linkevicius, T., Puisys, A., Steigmann, M., Vindasiute, E., & Linkeviciene, L.
Venue
Clinical Implant Dentistry and Related Research
Publisher
Wiley
Published
2014-03-28
Volume
17
Issue
6
Pages
1228-1236
ISSN
  • 1523-0899 (ISSN-L)
  • 1708-8208
OpenAlex
W2109989563
Cited by
225
References
0
FWCI
7.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of Vertical Soft Tissue Thickness on Crestal Bone Changes Around Implants with Platform Switching: A Comparative Clinical Study. https://app.cochat.ai/papers/10.1111/cid.12222
The paper
Linkevicius, T., Puisys, A., Steigmann, M., Vindasiute, E., & Linkeviciene, L. (2015). Influence of Vertical Soft Tissue Thickness on Crestal Bone Changes Around Implants with Platform Switching: A Comparative Clinical Study. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/cid.12222

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.