The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Influence of the keratinized mucosa on the stability of peri‐implant tissues and brushing discomfort: A 4‐year follow‐up study
Abstract
Objective: The purpose of the present prospective follow‐up study was to evaluate the long‐term influence of the peri‐implant keratinized mucosa (KM) on marginal bone level (MBL), peri‐implant tissues health, and brushing discomfort. Material and Methods: Eighty patients were initially recruited during their maintenance visit from January to October 2013 and allocated in two groups according to KM width around implants: Wide Group (KM ≥ 2 mm) and Narrow Group (KM < 2 mm). In the four‐year follow‐up examination (T4), marginal bone level (MBL), modified plaque index (mPI), probing depth (PD), clinical attachment level (CAL), bleeding on probing (BoP), and brushing discomfort (BD) were reassessed and compared to the initial assessments (T0). Mann–Whitney, Wilcoxon signed‐rank test, and a multilevel model were used for the statistical analysis. Results: Fifty‐four patients with 202 implants returned at T4. Mean mPI (0.91 ± 0.60), BoP (0.67 ± 0.21), and BD (12.28 ± 17.59) were higher in the Narrow Group than in the Wide Group (0.54 ± 0.48, 0.56 ± 0.26, and 4.25 ± 8.39, respectively). Marginal bone loss was higher in the Narrow Group (0.26 ± 0.71) than in the Wide Group (0.06 ± 0.48). Multilevel analysis suggested that KM width and time in function had a statistically significant effect on MBL. Conclusions: The findings of the present study indicate that KM width had an effect on MBL, plaque accumulation, tissue inflammation, and brushing discomfort over the studied period. Thus, the presence of a KM ≥ 2 mm around implants appears to have a protective effect on peri‐implant tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Faul, F., Erdfelder, E., Lang, A.-G., & Buchner, A. (2007) · Behavior Research Methods · doi:10.3758/bf03193146 · Cited by 65,971
The measurement of clinical pain intensity: a comparison of six methods
Jensen, M. P., Karoly, P., & Braver, S. (1986) · Pain · doi:10.1016/0304-3959(86)90228-9 · Cited by 3,275
Cited by
Tavelli, L., Barootchi, S., Avila‐Ortiz, G., Urban, I. A., Giannobile, W. V., & Wang, H. (2021) · Journal of Periodontology · doi:10.1002/jper.19-0716 · Cited by 336
Avila‐Ortiz, G., Gonzalez‐Martin, O., Couso‐Queiruga, E., & Wang, H. (2020) · Journal of Periodontology · doi:10.1002/jper.19-0566 · Cited by 268
Metadata
- Authors
- Perussolo, J., Souza, A. B., Matarazzo, F., Oliveira, R. P., & Araújo, M. G.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2018-11-15
- Volume
- 29
- Issue
- 12
- Pages
- 1177-1185
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2897826541
- Cited by
- 183
- References
- 2
- FWCI
- 16.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of the keratinized mucosa on the stability of peri‐implant tissues and brushing discomfort: A 4‐year follow‐up study. https://app.cochat.ai/papers/10.1111/clr.13381
- The paper
- Perussolo, J., Souza, A. B., Matarazzo, F., Oliveira, R. P., & Araújo, M. G. (2018). Influence of the keratinized mucosa on the stability of peri‐implant tissues and brushing discomfort: A 4‐year follow‐up study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.13381
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.