N,N‐dimethylacrylamide—A new sensitizer in the FreeStyle Libre glucose sensor
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Isobornyl acrylate (IBOA) has recently been identified as one sensitizer in the FreeStyle Libre glucose sensor. Analyses with gas chromatography‐mass spectrometry (GC‐MS) have indicated the presence of N,N‐dimethylacrylamide (DMAA) in the sensor. Material and methods: Seven patients were referred for patch testing after developing skin reactions when using FreeStyle Libre. All patients were patch tested with IBOA and DMAA. Two patients were tested with adhesive patches that had been removed from the sensors “as is,” and two patients were tested with acetone extracts of materials from the sensor. The extracts were analysed with GC‐MS. Results: Six patients reacted to both IBOA and DMAA, and one patient reacted only to DMAA. Positive reactions were also observed in both patients tested with the adhesive patch "as is". One patient reacted to both an extract of the adhesive patch and an extract of the sensor itself. When analysed with GC‐MS, IBOA was found in both extracts and DMAA was found in the extract of the sensor. Conclusion: Both IBOA and DMAA may be present in adhesives used in medical devices such as glucose sensors or insulin pumps, and should be patch tested when suspected contact allergic reactions to these products are investigated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Herman, A., Aerts, O., Baeck, M., Bruze, M., De Block, C., Goossens, A., Hamnerius, N., Huygens, S., Maiter, D., Tennstedt, D., et al. (2017) · Contact Dermatitis · doi:10.1111/cod.12866 · Cited by 192
Self-citationKamann, S., Aerts, O., & Heinemann, L. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818762946 · Cited by 85 · cited 1×
“According to the manufacturer of the adhesive patch, no IBOA is used in the adhesive in contact with the skin or in the adhesive used to fix the patch to the sensor.(12) However, in our analyses, we found that IBOA was also present in the extract of the adhesive patch that had been removed from the sensor, suggesting…”
Method
Cited by
Charleer, S., De Block, C., Van Huffel, L., Broos, B., Fieuws, S., Nobels, F., Mathieu, C., & Gillard, P. (2020) · Diabetes Care · doi:10.2337/dc19-1610 · Cited by 261
Fröhlich‐Reiterer, E., Elbarbary, N. S., Simmons, K., Buckingham, B., Humayun, K. N., Johannsen, J., Holl, R. W., Betz, S., & Mahmud, F. H. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13445 · Cited by 74
Rigo, R. S., Levin, L. E., Belsito, D. V., Garzon, M. C., Gandica, R., & Williams, K. M. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820918894 · Cited by 58
Herman, A., de Montjoye, L., & Baeck, M. (2020) · Contact Dermatitis · doi:10.1111/cod.13529 · Cited by 36
“For these 17 patients, four hypotheses must be considered: (i) while IBOA was already identified for the FreeStyle Libre sensor, DMAA was discovered later.(5) Thirteen patients were also tested with”
BackgroundSelf-citation
Metadata
- Authors
- Mowitz, M., Herman, A., Baeck, M., Isaksson, M., Antelmi, A., Hamnerius, N., Pontén, A., & Bruze, M.
- Venue
- Contact Dermatitis
- Publisher
- Wiley
- Published
- 2019-03-29
- Volume
- 81
- Issue
- 1
- Pages
- 27-31
- ISSN
- 0105-1873 (ISSN-L)
- 1600-0536
- OpenAlex
- W2917173978
- Cited by
- 80
- References
- 2
- FWCI
- 11.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: N,N‐dimethylacrylamide—A new sensitizer in the FreeStyle Libre glucose sensor. https://app.cochat.ai/papers/10.1111/cod.13243
- The paper
- Mowitz, M., Herman, A., Baeck, M., Isaksson, M., Antelmi, A., Hamnerius, N., Pontén, A., & Bruze, M. (2019). N,N‐dimethylacrylamide—A new sensitizer in the FreeStyle Libre glucose sensor. Contact Dermatitis. https://doi.org/10.1111/cod.13243
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.