Six‐minute walk test: a tool for predicting maximal aerobic power (VO2 max) in healthy adults
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Summary: Background: The 6‐min walk test (6 MWT) is cost‐effective and well‐documented field test for assessing functional exercise capacity and response to medical interventions in diverse patient groups, and predicting cardiorespiratory fitness among healthy people. Objective: Assessments of cardiorespiratory fitness in terms of maximal aerobic power (VO2 max) have great potential in public health monitoring to predict future health, early retirement and ability to independent living. This study aimed to develop a prediction model for VO2 max based on 6 MWT results among healthy adults. Design: The study comprised of pilot and validation studies. In validation study, seventy‐five 19‐ to 75‐year‐old adults (39 men, 36 women) were equipped with portable gas analyser and heart rate monitor. Participants performed 6 MWT on a 15‐m indoor track and maximal graded exercise test (GXT) on a treadmill. We evaluated performance of the developed prediction model among 1583 Finnish adults. Results: Participant's mean walking distance was 652 m (SD ± 74). Their mean VO2 max in GXT and O 2 uptake at the end of the 6 MWT were 34·4 ml kg−1 min−1 (SD ± 7·6) and 27·2 ml kg−1 min−1 (SD ± 6·5), respectively. For men, the best predictors for VO2 max were walking distance, age, BMI, heart rate at the end of 6 MWT and height, and for women, walking distance, age and weight. The predictors explained 82% and 79% of men's and women's measured VO2 max with the standard error of estimate of 3·6 ml kg−1 min−1 and 3·5 ml kg−1 min−1, respectively. Conclusion: The 6 MWT performed along a 15‐m track is a valid field test for predicting VO2 max of healthy adults with accuracy of about 1 MET.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Psychophysical bases of perceived exertion
BORG, G. A. V. (1982) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198205000-00012 · Cited by 16,580 · cited 1×
“Rating of perceived exertion (RPE) 6–20 (Borg, 1982), heart rate and distance walked in last lap were recorded the end of the test.”
BackgroundGlobal physical activity levels: surveillance progress, pitfalls, and prospects
Hallal, P. C., Andersen, L. B., Bull, F. C., Guthold, R., Haskell, W., & Ekelund, U. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60646-1 · Cited by 5,711 · cited 1×
“potential in public health monitoring to predict future health, early retirement, ability to independent living and need for care (Bull & Bauman, 2008; Hallal et al., 2012).”
BackgroundUnderstanding bland altman analysis
Giavarina, D. (2015) · Biochemia Medica · doi:10.11613/bm.2015.015 · Cited by 4,706 · cited 1×
“Bland–Altman difference plots were used to assess the 95% limits of agreements for the developed models (Giavarina, 2015).”
MethodKodama, S. (2009) · JAMA · doi:10.1001/jama.2009.681 · Cited by 3,035
An experimental study of physical fitness of Air Force personnel.
Balke, B., & Ware, R. W. (1959) · PubMed · Cited by 1,174
Six minute walking distance in healthy elderly subjects
Troosters, T., Gosselink, R., & Decramer, M. (1999) · European Respiratory Journal · doi:10.1034/j.1399-3003.1999.14b06.x · Cited by 1,042 · cited 1×
“In former studies, also track lengths of 50 and 20 m have been used (Lipkin et al., 1986; Stevens et al., 1999; Troosters et al., 1999; Beriault et al., 2009) .”
MethodBittner, V. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03510140062030 · Cited by 711
Six minute walking test for assessing exercise capacity in chronic heart failure.
Lipkin, D. P., Scriven, A. J., Crake, T., & Poole-Wilson, P. A. (1986) · BMJ · doi:10.1136/bmj.292.6521.653 · Cited by 560 · cited 1×
“In former studies, also track lengths of 50 and 20 m have been used (Lipkin et al., 1986; Stevens et al., 1999; Troosters et al., 1999; Beriault et al., 2009) .”
MethodReliability and Intensity of the Six-Minute Walk Test in Healthy Elderly Subjects
KERVIO, G., CARRE, F., & VILLE, N. S. (2003) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200301000-00025 · Cited by 317
A 2-km Walking Test for Assessing the Cardiorespiratory Fitness of Healthy Adults
Oja, P., Laukkanen, R., Pasanen, M., Tyry, T., & Vuori, I. (1991) · International Journal of Sports Medicine · doi:10.1055/s-2007-1024694 · Cited by 220 · cited 1×
“In the development study of UKK 2 km, the SEE for VO2max ranged from 9% to 15% and for the Rockport 1-mile test from 12% to 14% (Kline et al., 1987; Oja et al., 1991).”
MethodBurr, J. F., Bredin, S. S. D., Faktor, M. D., & Warburton, D. E. R. (2011) · The Physician and Sportsmedicine · doi:10.3810/psm.2011.05.1904 · Cited by 200 · cited 3×
“Burr et al. (2011) used in their 6MWT validation study a 20-m track.”
BackgroundMethodInfluentialComparison of Hallway and Treadmill Six-minute Walk Tests
STEVENS, D., ELPERN, E., SHARMA, K., SZIDON, P., ANKIN, M., & KESTEN, S. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.5.9808139 · Cited by 191 · cited 1×
“In former studies, also track lengths of 50 and 20 m have been used (Lipkin et al., 1986; Stevens et al., 1999; Troosters et al., 1999; Beriault et al., 2009) .”
MethodACSM’s Guidelines for Exercise Testing and Prescription, 7th Edition
Heath, E. H. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000189073.33400.04 · Cited by 188
Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method
Rosdahl, H., Gullstrand, L., Salier-Eriksson, J., Johansson, P., & Schantz, P. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1326-9 · Cited by 181 · cited 1×
“After health screening, participants were equipped with portable heart rate monitor (Polar T31, Kempele, Finland) and breath-by-breath portable metabolic analyser (Oxycon Mobile, Carefusion, Yorba Linda, CA, USA) (Rosdahl et al., 2010).”
MethodPhysical activity, cardiorespiratory fitness, and adiposity: contributions to disease risk
LaMonte, M. J., & Blair, S. N. (2006) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/01.mco.0000241662.92642.08 · Cited by 170
Reproducibility of the 6-minute Walk Test in Obese Adults
Beriault, K., Carpentier, A. C., Gagnon, C., Ménard, J., Baillargeon, J. P., Ardilouze, J. L., & Langlois, M. (2009) · International Journal of Sports Medicine · doi:10.1055/s-0029-1231043 · Cited by 163 · cited 1×
“In former studies, also track lengths of 50 and 20 m have been used (Lipkin et al., 1986; Stevens et al., 1999; Troosters et al., 1999; Beriault et al., 2009) .”
MethodRostagno, C., & Gensini, G. F. (2008) · Internal and Emergency Medicine · doi:10.1007/s11739-008-0130-6 · Cited by 122
An equation for prediction of energy expenditure of walking and running.
van der Walt, W. H., & Wyndham, C. H. (1973) · Journal of Applied Physiology · doi:10.1152/jappl.1973.34.5.559 · Cited by 112
Ekblom‐Bak, E., Hellénius, M.-L., Ekblom, Ö. B., Engström, L., & Ekblom, B. T. (2010) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e32833254f2 · Cited by 101
Malmberg, J. J., Miilunpalo, S. I., VUORI, I. M., Pasanen, M. E., Oja, P., & Haapanen, N. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.32304 · Cited by 97
Adiposity, physical fitness and incident diabetes: The physical activity longitudinal study
Katzmarzyk, P. T., Craig, C. L., & Gauvin, L. (2007) · Diabetologia · doi:10.1007/s00125-006-0554-3 · Cited by 97
Safety and Feasibility of a Health-Related Fitness Test Battery for Adults
Suni, J. H., Miilunpalo, S. I., Asikainen, T.-M., Laukkanen, R. M. T., Oja, P., Pasanen, M. E., Bös, K., & VUORI, I. M. (1998) · Physical Therapy · doi:10.1093/ptj/78.2.134 · Cited by 87 · cited 1×
“An exercise physiologist using the safety model developed for health-related fitness testing (Suni et al., 1998; Malmberg et al., 2002) performed health screening.”
MethodSelf-citationHusu, P., Suni, J., Vähä-Ypyä, H., Sievänen, H., Tokola, K., Valkeinen, H., Mäki-Opas, T., & Vasankari, T. (2016) · BMC Public Health · doi:10.1186/s12889-016-3591-y · Cited by 79 · cited 1×
“We applied the developed prediction equations to the data of the 6MWT collected in the PA and fitness subsample of National Health 2011 Survey (n = 1583) (Husu et al., 2016).”
MethodSelf-citationESTIMATION OF VO2MAX FROM A ONE-MILE TRACK WALK, GENDER, AGE, AND BODY-WEIGHT
KLINE, G. M., PORCARI, J., Hintermeister, R. A., FREEDSON, P., WARD, A., McCarron, R., ROSS, J., & Rippe, J. (1987) · ScholarWorks@UMassAmherst (University of Massachusetts Amherst) · Cited by 46
Physical Fitness and Carotid Atherosclerosis in Men
Lee, C. D., Jae, S. Y., Iribarren, C., Gabriel, K. P., & Choi, Y. (2009) · International Journal of Sports Medicine · doi:10.1055/s-0029-1224179 · Cited by 25
Consistent risk factor monitoring systems underpins good public health practice
Bull, F., & Bauman, A. E. (2008) · Preventive Medicine · doi:10.1016/j.ypmed.2008.05.004 · Cited by 6
Cited by
Meadley, B., Wolkow, A. P., Smith, K., Perraton, L., Bowles, K.-A., & Bonham, M. P. (2022) · Prehospital Emergency Care · doi:10.1080/10903127.2021.1949081 · Cited by 12
“per day 29 (±22) [18, 40] 27 (±16) [19, 35] 29 (±19) [20, 38] 30 (±22) [19, 41] 0.”
Metadata
- Authors
- Mänttäri, A., Suni, J., Sievänen, H., Husu, P., Vähä‐Ypyä, H., Valkeinen, H., Tokola, K., & Vasankari, T.
- Venue
- Clinical Physiology and Functional Imaging
- Publisher
- Wiley
- Published
- 2018-05-31
- Volume
- 38
- Issue
- 6
- Pages
- 1038-1045
- ISSN
- 1475-0961 (ISSN-L)
- 1475-097X
- OpenAlex
- W2805491049
- Cited by
- 175
- References
- 26
- FWCI
- 17.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.