The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Management of digital eye strain
Abstract
Digital eye strain, an emerging public health issue, is a condition characterised by visual disturbance and/or ocular discomfort related to the use of digital devices and resulting from a range of stresses on the ocular environment. This review aims to provide an overview of the extensive literature on digital eye strain research with particular reference to the clinical management of symptoms. As many as 90 per cent of digital device users experience symptoms of digital eye strain. Many studies suggest that the following factors are associated with digital eye strain: uncorrected refractive error (including presbyopia), accommodative and vergence anomalies, altered blinking pattern (reduced rate and incomplete blinking), excessive exposure to intense light, closer working distance, and smaller font size. Since a symptom may be caused by one or more factors, a holistic approach should be adopted. The following management strategies have been suggested: (i) appropriate correction of refractive error, including astigmatism and presbyopia; (ii) management of vergence anomalies, with the aim of inducing or leaving a small amount of heterophoria (~1.5Δ Exo); (iii) blinking exercise/training to maintain normal blinking pattern; (iv) use of lubricating eye drops (artificial tears) to help alleviate dry eye‐related symptoms; (v) contact lenses with enhanced comfort, particularly at end‐of‐day and in challenging environments; (vi) prescription of colour filters in all vision correction options, especially blue light‐absorbing filters; and (vii) management of accommodative anomalies. Prevention is the main strategy for management of digital eye strain, which involves: (i) ensuring an ergonomic work environment and practice (through patient education and the implementation of ergonomic workplace policies); and (ii) visual examination and eye care to treat visual disorders. Special consideration is needed for people at a high risk of digital eye strain, such as computer workers and contact lens wearers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevalence of dry eye syndrome among US women
Schaumberg, D. A., Sullivan, D. A., Buring, J. E., & Dana, M. R. (2003) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(03)00218-6 · Cited by 1,225
Visual Discomfort and Visual Fatigue of Stereoscopic Displays: A Review
Lambooij, M., Fortuin, M., Heynderickx, I., & IJsselsteijn, W. (2009) · Journal of Imaging Science and Technology · doi:10.2352/j.imagingsci.technol.2009.53.3.030201 · Cited by 1,006
Computer Vision Syndrome: A Review
Blehm, C., Vishnu, S., Khattak, A., Mitra, S., & Yee, R. W. (2005) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2005.02.008 · Cited by 860
Computer vision syndrome: a review of ocular causes and potential treatments
Rosenfield, M. (2011) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2011.00834.x · Cited by 726
Prevalence of Dry Eye Disease Among US Men: Estimates From the Physicians' Health Studies
Schaumberg, D. A. (2009) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2009.103 · Cited by 551
Analysis of blink rate patterns in normal subjects
Bentivoglio, A. R., Bressman, S. B., Cassetta, E., Carretta, D., Tonali, P., & Albanese, A. (1997) · Movement Disorders · doi:10.1002/mds.870120629 · Cited by 512
Dry Eyes and Video Display Terminals
Tsubota, K., & Nakamori, K. (1993) · New England Journal of Medicine · doi:10.1056/nejm199302253280817 · Cited by 435
Prevalence of Dry Eye Disease among Japanese Visual Display Terminal Users
Uchino, M., Schaumberg, D. A., Dogru, M., Uchino, Y., Fukagawa, K., Shimmura, S., Satoh, T., Takebayashi, T., & Tsubota, K. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2008.06.022 · Cited by 393
Age‐related maculopathy and the impact of blue light hazard
Algvere, P. V., Marshall, J., & Seregard, S. (2006) · Acta Ophthalmologica Scandinavica · doi:10.1111/j.1600-0420.2005.00627.x · Cited by 392
Computer vision syndrome: a study of knowledge and practices in university students
Reddy, S. C., Low, C., Lim, Y., et al. (2013) · Nepalese Journal of Ophthalmology · doi:10.3126/nepjoph.v5i2.8707 · Cited by 282
Cited by
Digital Eye Strain- A Comprehensive Review
Kaur, K., Gurnani, B., Nayak, S., Deori, N., Kaur, S., Jethani, J., Singh, D., Agarkar, S., Hussaindeen, J. R., Sukhija, J., et al. (2022) · Ophthalmology and Therapy · doi:10.1007/s40123-022-00540-9 · Cited by 313
Metaverse ethics: exploring the social implications of the metaverse
Yasuda, A. (2025) · AI and Ethics · doi:10.1007/s43681-024-00507-5 · Cited by 27
Forensic DNA Interpretation and Human Factors: Improving the Practice Through a Systems Approach
Taylor, M. K. (2024) · doi:10.6028/nist.ir.8503 · Cited by 14
Metadata
- Authors
- Coles‐brennan, C., Sulley, A., & Young, G.
- Venue
- Clinical and Experimental Optometry
- Publisher
- Informa UK Limited
- Published
- 2019-01
- Volume
- 102
- Issue
- 1
- Pages
- 18-29
- ISSN
- 0816-4622 (ISSN-L)
- 1444-0938
- OpenAlex
- W2803480332
- Cited by
- 324
- References
- 54
- FWCI
- 24.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Management of digital eye strain. https://app.cochat.ai/papers/10.1111/cxo.12798
- The paper
- Coles‐brennan, C., Sulley, A., & Young, G. (2019). Management of digital eye strain. Clinical and Experimental Optometry. https://doi.org/10.1111/cxo.12798
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.