CoChat

Review of methods for measuring β‐cell function: Design considerations from the Restoring Insulin Secretion ( RISE ) Consortium

Open access
Hannon, Tamara S., Kahn, Steven E., Utzschneider, Kristina M., Buchanan, Thomas A., Nadeau, Kristen J., Zeitler, Philip S., Ehrmann, David A., Arslanian, Silva A., Caprio, Sonia, Edelstein, Sharon L., Savage, Peter J., Mather, Kieren J., for the RISE Consortium · 2018 · Diabetes, Obesity and Metabolism
Cited by 87

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Abstract

The R estoring I nsulin S ecretion ( RISE ) study was initiated to evaluate interventions to slow or reverse the progression of β‐cell failure in type 2 diabetes ( T2D ). To design the RISE study, we undertook an evaluation of methods for measurement of β‐cell function and changes in β‐cell function in response to interventions. In the present paper, we review approaches for measurement of β‐cell function, focusing on methodologic and feasibility considerations. Methodologic considerations included: (1) the utility of each technique for evaluating key aspects of β‐cell function (first‐ and second‐phase insulin secretion, maximum insulin secretion, glucose sensitivity, incretin effects) and (2) tactics for incorporating a measurement of insulin sensitivity in order to adjust insulin secretion measures for insulin sensitivity appropriately. Of particular concern were the capacity to measure β‐cell function accurately in those with poor function, as is seen in established T2D , and the capacity of each method for demonstrating treatment‐induced changes in β‐cell function. Feasibility considerations included: staff burden, including time and required methodological expertise; participant burden, including time and number of study visits; and ease of standardizing methods across a multicentre consortium. After this evaluation, we selected a 2‐day measurement procedure, combining a 3‐hour 75‐g oral glucose tolerance test and a 2‐stage hyperglycaemic clamp procedure, augmented with arginine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/dom.13005

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 36 references

Cited by

See all 87

Metadata

Authors
Hannon, T. S., Kahn, S. E., Utzschneider, K. M., Buchanan, T. A., Nadeau, K. J., Zeitler, P. S., Ehrmann, D. A., Arslanian, S. A., Caprio, S., Edelstein, S. L., Savage, P. J., Mather, K. J., & for the RISE Consortium
Venue
Diabetes, Obesity and Metabolism
Publisher
Wiley
Published
2017-06-22
Volume
20
Issue
1
Pages
14-24
ISSN
  • 1462-8902 (ISSN-L)
  • 1463-1326
OpenAlex
W2613617001
Cited by
87
References
36
FWCI
6.32
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Review of methods for measuring β‐cell function: Design considerations from the Restoring Insulin Secretion ( RISE ) Consortium. https://app.cochat.ai/papers/10.1111/dom.13005
The paper
Hannon, T. S., Kahn, S. E., Utzschneider, K. M., Buchanan, T. A., Nadeau, K. J., Zeitler, P. S., Ehrmann, D. A., Arslanian, S. A., Caprio, S., Edelstein, S. L., Savage, P. J., Mather, K. J., & for the RISE Consortium. (2018). Review of methods for measuring β‐cell function: Design considerations from the Restoring Insulin Secretion ( RISE ) Consortium. Diabetes, Obesity and Metabolism. https://doi.org/10.1111/dom.13005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.