Effectiveness and safety of early insulin glargine administration in combination with continuous intravenous insulin infusion in the management of diabetic ketoacidosis: a randomized controlled trial
Abstract
Aim To determine the effectiveness and safety of early combination of insulin glargine with intravenous (IV) insulin infusion compared with IV insulin infusion alone in the management of diabetic ketoacidosis (DKA). Methods This was a single-centre, open-label, randomized controlled trial of adults aged 18 years or older diagnosed with DKA. The 'early glargine' group was given subcutaneous insulin glargine 0.3 units/kg within the first 3 hours of DKA diagnosis, in addition to the standard IV insulin infusion. The control group received standard IV insulin treatment only. The primary outcome was the time to DKA resolution. The other outcomes included rebound hyperglycaemia, mortality, hypoglycaemia and hypokalaemia, as well as the length of hospital stay (LOS). Results A total of 60 patients (30 patients per group) were enrolled. Most patients (76.7%) had type 2 diabetes. Both groups were similar in baseline characteristics, except for higher serum beta-hydroxybutyrate and lower pH levels in the early glargine group. The mean ± standard deviation time to DKA resolution in the early glargine group was significantly faster than the control group (9.89 ± 3.81 vs. 12.73 ± 5.37 hours; P = .022). The median (interquartile range) LOS was significantly shorter in the early glargine group than in the control group (4.75 [3.53-8.96] vs. 15.25 [5.71-26.38] days; P = .024). The incidence of rebound hyperglycaemia, all-cause mortality, hypoglycaemia and hypokalaemia was similar between the…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Emerging data from studies in people with hyperglycemia with and without diabetic ketoacidosis (DKA) show that the administration of a low dose (0.15-0.3 units/kg) of basal insulin analog in addition to intravenous insulin infusion may reduce the duration of insulin infusion and length of hospital stay and prevent rebound hyperglycemia without increased risk of hypoglycemia.
“Emerging data from studies in people with hyperglycemia with and without diabetic ketoacidosis (DKA) show that the administration of a low dose (0.15-0.3 units/kg) of basal insulin analog in addition to intravenous insulin infusion may reduce the duration of insulin infusion and length of hospital stay and prevent rebound hyperglycemia without increased risk of hypoglycemia (64)(65)(66)(67).”
From 16. Diabetes Care in the Hospital: Standards of Care in Diabetes—2026 (2026) · cites this paper as [64]
Administration of a low dose of basal insulin analog in addition to intravenous insulin infusion early in treatment may prevent rebound hyperglycemia without increased risk of hypoglycemia.
“Studies have reported that the administration of a low dose of basal insulin analog in addition to intravenous insulin infusion early in the course of treatment may prevent rebound hyperglycemia without increased risk of hypoglycemia (64-66,179).”
From 16. Diabetes Care in the Hospital: Standards of Care in Diabetes—2026 (2026) · cites this paper as [64]
Cites
Beck, R. W., Bergenstal, R. M., Riddlesworth, T. D., & Kollman, C. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0362 · Cited by 42 · see citing works
Lim, Y., Ohn, J. H., Jeong, J., Ryu, J., Kim, S.-W., Cho, J. H., Park, H.-S., Kim, H. W., Lee, J., Kim, E. S., et al. (2022) · Endocrinology and Metabolism · doi:10.3803/enm.2021.1341 · Cited by 14 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Hyperglycemic crises in adults with diabetes: a consensus report
Umpierrez, G. E., Davis, G. M., ElSayed, N. A., Fadini, G. P., Galindo, R. J., Hirsch, I. B., Klonoff, D. C., McCoy, R. G., Misra, S., Gabbay, R. A., et al. (2024) · Diabetes Care · doi:10.2337/dci24-0032 · Cited by 278 · see citing works
16. Diabetes Care in the Hospital: Standards of Care in Diabetes—2026
American Diabetes Association Professional Practice Committee for Diabetes*, Bajaj, M., McCoy, R. G., Balapattabi, K., Bannuru, R. R., Bellini, N. J., Bennett, A. K., Beverly, E. A., Briggs Early, K., ChallaSivaKanaka, S., et al. (2026) · Diabetes Care · doi:10.2337/dc26-s016 · Cited by 80 · see citing works
- Authors
- Thammakosol, K., & Sriphrapradang, C.
- Affiliations
- Mahidol University (TH)
- Corresponding author
- Sriphrapradang, Chutintorn
- Venue
- Diabetes, Obesity and Metabolism
- Publisher
- Wiley
- Published
- 2022-12-20
- Volume
- 25
- Issue
- 3
- Pages
- 815-822
- ISSN
- 1462-8902 (ISSN-L)
- 1463-1326
- OpenAlex
- W4312018647
- Cited by
- 38
- References
- 2
- Citations by year
- 2026: 6 · 2025: 18 · 2024: 12 · 2023: 2
- FWCI
- 5.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Diabetes Obesity and Metabolism (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- diabetic ketoacidosis, insulin glargine, continuous intravenous insulin infusion, early insulin therapy, length of hospital stay, hypoglycemia, hypokalemia, type 2 diabetes
- MeSH terms
- Insulin Glargine, Adult, Diabetes Mellitus, Type 2, Humans, Hyperglycemia, Hypoglycemia, Hypoglycemic Agents, Hypokalemia, Insulin, Diabetic Ketoacidosis, Insulin, Regular, Human
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review