The DOI matches its Crossref record.
Adverse events related to extraoperative invasive EEG monitoring with subdural grid electrodes: A systematic review and meta‐analysis
Open accessAbstract
Summary: Purpose: Implantation of subdural grids and invasive electroencephalography (EEG) monitoring is important to define the ictal‐onset zone and eloquent cortex in selected patients with medically refractory epilepsy. The objective of this systematic review is to summarize data about adverse events related to this procedure. Methods: English‐language studies published up to J uly 2012, reporting such adverse events were reviewed. Outcome measures included demographic variables; surgical protocol including number of subdural electrodes implanted per patient, duration of monitoring, antibiotic, and steroid prophylaxis; and adverse events. Key Findings: Twenty‐one studies were identified including a total of 2,542 patients. The reported mean number of electrodes per patient and duration of monitoring varied from 52 to 95 and 5 to 17 days, respectively. There is a trend toward more uniform use of antibiotics and steroids in the perioperative period. Neurologic infections (pooled prevalence 2.3%, 95% confidence interval 1.5–3.1), superficial infections (3.0%, 1.9–4.1), intracranial hemorrhage (4.0%, 3.2–4.8), and elevated intracranial pressure (2.4%, 1.5–3.3) were found to be the most common adverse events. Up to 3.5% of patients required additional surgical procedure(s) for management of these adverse events. Increased number of electrodes (≥67) was found to be independently associated with increased incidence of adverse events. Significance: Although providing critical information for patients with medically refractory epilepsy, subdural grids implantation and invasive EEG monitoring entails risks of infection, hemorrhage, and elevated intracranial pressure. The prevalence estimates, likely to be conservative due to selective reporting, are expected to be helpful in counseling patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Resective Epilepsy Surgery for Drug-Resistant Focal Epilepsy: A Review
Jobst, B. C., & Cascino, G. D. (2015) · JAMA · doi:10.1001/jama.2014.17426 · Cited by 665
Mullin, J. P., Shriver, M., Alomar, S., Najm, I., Bulacio, J., Chauvel, P., & Gonzalez‐Martinez, J. (2016) · Epilepsia · doi:10.1111/epi.13298 · Cited by 434
Lewis, P. M., Ackland, H. M., Lowery, A. J., & Rosenfeld, J. V. (2015) · Brain Research · doi:10.1016/j.brainres.2014.11.020 · Cited by 228
Metadata
- Authors
- Arya, R., Mangano, F. T., Horn, P. S., Holland, K. D., Rose, D. F., & Glauser, T. A.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2013-01-07
- Volume
- 54
- Issue
- 5
- Pages
- 828-839
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W1964237496
- Cited by
- 221
- References
- 0
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adverse events related to extraoperative invasive EEG monitoring with subdural grid electrodes: A systematic review and meta‐analysis. https://app.cochat.ai/papers/10.1111/epi.12073
- The paper
- Arya, R., Mangano, F. T., Horn, P. S., Holland, K. D., Rose, D. F., & Glauser, T. A. (2013). Adverse events related to extraoperative invasive EEG monitoring with subdural grid electrodes: A systematic review and meta‐analysis. Epilepsia. https://doi.org/10.1111/epi.12073
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.