Standardized Computer‐based Organized Reporting of EEG: SCORE
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Summary: The electroencephalography (EEG) signal has a high complexity, and the process of extracting clinically relevant features is achieved by visual analysis of the recordings. The interobserver agreement in EEG interpretation is only moderate. This is partly due to the method of reporting the findings in free‐text format. The purpose of our endeavor was to create a computer‐based system for EEG assessment and reporting, where the physicians would construct the reports by choosing from predefined elements for each relevant EEG feature, as well as the clinical phenomena (for video‐EEG recordings). A working group of EEG experts took part in consensus workshops in D ianalund, D enmark, in 2010 and 2011. The faculty was approved by the C ommission on E uropean A ffairs of the I nternational L eague Against Epilepsy (ILAE). The working group produced a consensus proposal that went through a pan‐E uropean review process, organized by the E uropean C hapter of the I nternational F ederation of Clinical Neurophysiology. The Standardised Computer‐based Organised Reporting of EEG (SCORE) software was constructed based on the terms and features of the consensus statement and it was tested in the clinical practice. The main elements of SCORE are the following: personal data of the patient, referral data, recording conditions, modulators, background activity, drowsiness and sleep, interictal findings, “episodes” (clinical or subclinical events), physiologic patterns, patterns of uncertain significance, artifacts, polygraphic channels, and diagnostic significance. The following specific aspects of the neonatal EEG s are scored: alertness, temporal organization, and spatial organization. For each EEG finding, relevant features are scored using predefined terms. Definitions are provided for all EEG terms and features. SCORE can potentially improve the quality of EEG assessment and reporting; it will help incorporate the results of computer‐assisted analysis into the report, it will make possible the build‐up of a multinational database, and it will help in training young neurophysiologists.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Berg, A. T., Berkovic, S. F., Brodie, M. J., Buchhalter, J., Cross, J. H., Van Emde Boas, W., Engel, J., French, J., Glauser, T. A., Mathern, G. W., et al. (2010) · Epilepsia · doi:10.1111/j.1528-1167.2010.02522.x · Cited by 4,363 · cited 1×
“The table includes ILAE seizure classification (Commission, 1981; Berg et al., 2010).”
MethodSelf-citation
Cited by
Kane, N., Acharya, J., Beniczky, S., Caboclo, L., Finnigan, S., Kaplan, P. W., Shibasaki, H., Pressler, R., & van Putten, M. J. A. M. (2017) · Clinical Neurophysiology Practice · doi:10.1016/j.cnp.2017.07.002 · Cited by 517
Self-citationUnified EEG terminology and criteria for nonconvulsive status epilepticus
Beniczky, S., Hirsch, L. J., Kaplan, P. W., Pressler, R., Bauer, G., Aurlien, H., Brøgger, J. C., & Trinka, E. (2013) · Epilepsia · doi:10.1111/epi.12270 · Cited by 481
Self-citationLeitinger, M., Trinka, E., Gardella, E., Rohracher, A., Kalss, G., Qerama, E., Höfler, J., Hess, A., Zimmermann, G., Kuchukhidze, G., et al. (2016) · The Lancet Neurology · doi:10.1016/s1474-4422(16)30137-5 · Cited by 320
Self-citationClinical utility of EEG in diagnosing and monitoring epilepsy in adults
Tatum, W. O., Rubboli, G., Kaplan, P. W., Mirsatari, S. M., Radhakrishnan, K., Gloss, D., Caboclo, L. O., Drislane, F. W., Koutroumanidis, M., Schomer, D. L., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.01.019 · Cited by 314
Self-citationMultimodal prediction of residual consciousness in the intensive care unit: the CONNECT-ME study
Amiri, M., Fisher, P. M., Raimondo, F., Sidaros, A., Cacic Hribljan, M., Othman, M. H., Zibrandtsen, I., Albrechtsen, S. S., Bergdal, O., Hansen, A. E., et al. (2023) · Brain · doi:10.1093/brain/awac335 · Cited by 89
Self-citation
Metadata
- Authors
- Beniczky, S., Aurlien, H., Brøgger, J. C., Fuglsang‐Frederiksen, A., Martins‐da‐Silva, A., Trinka, E., Visser, G., Rubboli, G., Hjalgrim, H., Stefan, H., Rosén, I., Zarubova, J., Dobesberger, J., Alving, J., Andersen, K. V., Fabricius, M., Atkins, M. D., Neufeld, M., Plouin, P., Marusic, P., Pressler, R., Mameniskiene, R., Hopfengärtner, R., van Emde Boas, W., & Wolf, P.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2013-03-18
- Volume
- 54
- Issue
- 6
- Pages
- 1112-1124
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W1997839794
- Cited by
- 123
- References
- 1
- FWCI
- 3.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Standardized Computer‐based Organized Reporting of EEG: SCORE. https://app.cochat.ai/papers/10.1111/epi.12135
- The paper
- Beniczky, S., Aurlien, H., Brøgger, J. C., Fuglsang‐Frederiksen, A., Martins‐da‐Silva, A., Trinka, E., Visser, G., Rubboli, G., Hjalgrim, H., Stefan, H., Rosén, I., Zarubova, J., Dobesberger, J., Alving, J., Andersen, K. V., Fabricius, M., Atkins, M. D., Neufeld, M., Plouin, P., . . . Wolf, P. (2013). Standardized Computer‐based Organized Reporting of EEG: SCORE. Epilepsia. https://doi.org/10.1111/epi.12135
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.