The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Interrater agreement for Critical Care EEG Terminology
Open accessAbstract
Summary: Objective: The interpretation of critical care electroencephalography (EEG) studies is challenging because of the presence of many periodic and rhythmic patterns of uncertain clinical significance. Defining the clinical significance of these patterns requires standardized terminology with high interrater agreement (IRA). We sought to evaluate IRA for the final, published American Clinical Neurophysiology Society (ACNS)–approved version of the critical care EEG terminology (2012 version). Our evaluation included terms not assessed previously and incorporated raters with a broad range of EEG reading experience. Methods: After reviewing a set of training slides, 49 readers independently completed a Web‐based test consisting of 11 identical questions for each of 37 EEG samples (407 questions). Questions assessed whether a pattern was an electrographic seizure; pattern location (main term 1), pattern type (main term 2); and presence and classification of eight other key features (“plus” modifiers, sharpness, absolute and relative amplitude, frequency, number of phases, fluctuation/evolution, and the presence of “triphasic” morphology). Results: IRA statistics (κ values) were almost perfect (90–100%) for seizures, main terms 1 and 2, the +S modifier (superimposed spikes/sharp waves or sharply contoured rhythmic delta activity), sharpness, absolute amplitude, frequency, and number of phases. Agreement was substantial for the +F (superimposed fast activity) and +R (superimposed rhythmic delta activity) modifiers (66% and 67%, respectively), moderate for triphasic morphology (58%), and fair for evolution (21%). Significance: IRA for most terms in the ACNS critical care EEG terminology is high. These terms are suitable for multicenter research on the clinical significance of critical care EEG patterns. A PowerPoint slide summarizing this article is available for download in the Supporting Information section http://dx.doi.org/10.1111/epi.12653/supinfo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High agreement but low Kappa: I. the problems of two paradoxes
Feinstein, A. R., & Cicchetti, D. V. (1990) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(90)90158-l · Cited by 3,034
Computing inter‐rater reliability and its variance in the presence of high agreement
Gwet, K. L. (2008) · British Journal of Mathematical and Statistical Psychology · doi:10.1348/000711006x126600 · Cited by 2,167
Cited by
American Clinical Neurophysiology Society's Standardized Critical Care EEG Terminology: 2021 Version
Hirsch, L. J., Fong, M. W. K., Leitinger, M., LaRoche, S. M., Beniczky, S., Abend, N. S., Lee, J. W., Wusthoff, C. J., Hahn, C. D., Westover, M. B., et al. (2021) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000806 · Cited by 1,130
Self-citationStandardized EEG interpretation accurately predicts prognosis after cardiac arrest
Westhall, E., Rossetti, A. O., van Rootselaar, A.-F., Wesenberg Kjaer, T., Horn, J., Ullén, S., Friberg, H., Nielsen, N., Rosén, I., Åneman, A., et al. (2016) · Neurology · doi:10.1212/wnl.0000000000002462 · Cited by 417
Leitinger, M., Trinka, E., Gardella, E., Rohracher, A., Kalss, G., Qerama, E., Höfler, J., Hess, A., Zimmermann, G., Kuchukhidze, G., et al. (2016) · The Lancet Neurology · doi:10.1016/s1474-4422(16)30137-5 · Cited by 320
Clinical utility of EEG in diagnosing and monitoring epilepsy in adults
Tatum, W. O., Rubboli, G., Kaplan, P. W., Mirsatari, S. M., Radhakrishnan, K., Gloss, D., Caboclo, L. O., Drislane, F. W., Koutroumanidis, M., Schomer, D. L., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.01.019 · Cited by 314
Rodriguez Ruiz, A., Vlachy, J., Lee, J. W., Gilmore, E. J., Ayer, T., Haider, H. A., Gaspard, N., Ehrenberg, J. A., Tolchin, B., Fantaneanu, T. A., et al. (2017) · JAMA Neurology · doi:10.1001/jamaneurol.2016.4990 · Cited by 290
Self-citation
Metadata
- Authors
- Gaspard, N., Hirsch, L. J., LaRoche, S. M., Hahn, C. D., Westover, M. B., & the Critical Care EEG Monitoring Research Consortium
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2014-06-02
- Volume
- 55
- Issue
- 9
- Pages
- 1366-1373
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W2034042493
- Cited by
- 181
- References
- 2
- FWCI
- 9.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interrater agreement for Critical Care EEG Terminology. https://app.cochat.ai/papers/10.1111/epi.12653
- The paper
- Gaspard, N., Hirsch, L. J., LaRoche, S. M., Hahn, C. D., Westover, M. B., & the Critical Care EEG Monitoring Research Consortium. (2014). Interrater agreement for Critical Care EEG Terminology. Epilepsia. https://doi.org/10.1111/epi.12653
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.